9.2 Notes on Maintenance Procedures
9-6
HW0484074
HW0484074
3. Remove the battery pack from the battery holder.
4. Connect the new battery pack to an unconnected connector on the circuit board.
5. Remove the old battery pack from the circuit board.
6. Mount the new battery pack to the battery holder.
7. Reinstall the cover plate and fix it with the plate fastening screws.
Make sure to connect the new battery pack before removing the old one so that the
encoder absolute data will not disappear.
Do not allow plate to pinch the cables when reinstalling the plate.
NOTE
NOTE