9.2 Notes on Maintenance Procedures
9-5
HW0484074
HW0484074
9.2
Notes on Maintenance Procedures
9.2.1
Battery Pack Replacement
If the battery alarm occurs in the NX100, replace the battery pack according to the following
procedure:
Fig. 20 Battery Pack Location
Fig. 21 Battery Pack Connection
1. Turn OFF the NX100 main power supply.
2. Remove the cover plate fixing screws from the connector base and pull out the battery
pack to replace with a new one.
Cover plate fixing screw
Cover plate
Connector base
Battery pack
Support
AIR
2BC
1BC
3BC
Connector
Battery pack before
replacement
See the step 5
New battery pack
Circuit board
See the step 4