บ٢ʰʕʍʒ
HYDRAULIC UNIT
94
11
บ٢ʰʕʍʒ
HYDRAULIC UNIT
11-1
ίަͽഈɁา̜ᬱ
Precautions when Performing Maintenance Work
8
Բ᪙
8
DANGER
ൡಽໃɥȪɖȪȹȢȳȨȗǿ
Turn OFF the main power.
7
า
7
CAUTION
1.
บȟႱࢠȾນߵȪȹȗɞȻȠɂʧʽʡɑȲɂൡಽ᪩Ɂȝ
ȰɟȟȕɝɑȬǿࣷᇋɿ˂ʝʃᩌȾȧᣵፅȢȳȨȗǿ
1.
If the oil level decreases rapidly, the pump unit or the
machine may be malfunctioning. Contact the Mori Seiki
Service Department for assistance.
2.
บᦀɥඩȪȢίધȪǾʧʽʡȟሳɥȗᣅɑȽȗɛșȾ
ȪȹȢȳȨȗǿ
2.
Maintain oil at the correct level to prevent air being
suctioned through the pump unit.
3.
บɂࢠȾȠɟȗȽৰȺȕɞɛșከျȪȹȢȳȨȗǿ
3.
Keep oil free from contamination.
4.
บ٢ʉʽɹȟɟɞȻบɥȠɟȗȽৰȾίȹȭǾʧʽʡ
ႱࢠɁՁىȻȽɝɑȬǿ
4.
If foreign matter accumulates in the tank, oil cannot be
kept free from contamination, causing pump damage.
5.
ʳʂɲ˂ʉȟᄻᝇɑɝȬɞȻบ٢˨ɁՁىȾȽɝɑȬǿ
5.
Clogged radiator causes oil pressure to be raised.
6.
ɿɹʁʱʽʃʒʶ˂ʔȟᄻᝇɑɝȬɞȻᥓከɗบ٢ʧʽʡ
ȟᆍૺȬɞȝȰɟȟȕɝɑȬǿ
6.
Clogged suction strainer causes pumps and piping
damage.
7.
٢ӌȟᤛඩϏȾᜫްȨɟȹȗȽȗȻบ٢ʰʕʍʒɁ᪩ɗ
ᆍૺȾȷȽȟɝɑȬǿ
7.
If the oil pressure setting is incorrect, hydraulic unit
malfunction and damage may result.
1
บɁሗ᭒Ⱦȷȗȹɂ
1
For oil types, refer to “OILS” (page 59).
11-2
บᦀɁཟ೫
/
บɁᛃፈ
Checking Oil Level/Replenishing Oil
บȟบᬂɁ˩᪅፷ɛɝ˩ȾȕɞȻȠɂൡಽໃɥȪɖȪǾ
ᛃፈȬɞǿ
Turn OFF the main power and supply oil when the oil level is
lower than the lower limit on the oil level gage.
11-3
บɁ̬૰
Replacing Oil
ᴹਖ਼ᬲᴻ
<Procedure>
1)
ൡಽໃɥȪɖȬɞǿ
1)
Turn OFF the main power.
Oil Level Gage
Fill Port Cap
บᬂ
ፈบՠɷʭʍʡ
Summary of Contents for NL1500/500
Page 8: ......
Page 9: ...CONTENTS FOR SAFE MACHINE OPERATION REGULAR MAINTENANCE TROUBLESHOOTING INDEX...
Page 10: ......
Page 19: ...FOR SAFE MACHINE OPERATION...
Page 50: ......
Page 51: ...1 1 CHAPTER 1 CHAPTER 1 REGULAR MAINTENANCE...
Page 167: ...2 2 CHAPTER 2 CHAPTER 2 TROUBLESHOOTING...
Page 181: ...181 ZERO POINT RETURN COMMAND ALARM TRIGGERED X X Axis Z Z Axis Y Y Axis...
Page 232: ......
Page 240: ......
Page 242: ......