1.
Inspect the pressure gage periodically. If not set at the
correct value, adjustment is necessary.
ᵘ̷ᡵ̜ǾൡಽɁ᪩ᵚ
[Serious injury/Machine failure]
2.
ᯚͽഈɂǾާްȪȲɂȪȧɑȲɂͽഈիɥΈႊȪȹȢȳ
ȨȗǿʚʳʽʃɥࡓȪǾ̷ᡵ̜ȾȷȽȟɝɑȬǿ
2.
Use a ladder or service platform when working in
elevated places. Loss of balance may result in serious
injury.
16-2
ሳ٢Ɂཟ೫Ȼᝩ
Air Pressure Inspection and Adjustment
ᴹਖ਼ᬲᴻ
<Procedure>
1)
ʚʵʠɥࡿȾوȪǾ٢᎔ሳɥΖፈȬɞǿ
1)
Supply the compressed air by rotating the valve CCW.
2)
ሳ٢ȟ
0.5 MPa
ᴥ፲ᓨʨ˂ɹᴦȾᜫްȨɟȹȗɞȞᆬᝓȬ
ɞǿ
2)
Check that the pressure gage is set at 0.5 MPa (green
mark).
3)
ᝩȟ॒ᛵȽکնɂǾ٢ӌᝩʘʠɥ˩ȾऀȠ˩ȥǾوȪ
ȹᝩȬɞǿ
3)
If necessary, pull the pressure adjustment knob downward
and rotate it to adjust the pressure.
ۄ٢ᴷ
ʘʠɥծȾوȬǿ
Increasing pressure:
Rotate the knob CW.
ນ٢ᴷ
ʘʠɥࡿȾوȬǿ
Reducing pressure:
Rotate the knob CCW.
2
าᜤ
2
NOTE
ᝩȺȠȽȗکնɂǾࡾکϫɁሳ٢ໃɥᆬᝓȪȹȢȳȨȗǿ
If the pressure cannot be adjusted, check the plant side air source.
Pressure Gage
Adjusting Knob
Air Filter
Manual Drain Cock
Valve
٢ӌ
ᝩʘʠ
ɲɬʟɭʵʉ
ਖ਼Ӧʓʶʽɽʍɹ
ʚʵʠ
Summary of Contents for NL1500/500
Page 8: ......
Page 9: ...CONTENTS FOR SAFE MACHINE OPERATION REGULAR MAINTENANCE TROUBLESHOOTING INDEX...
Page 10: ......
Page 19: ...FOR SAFE MACHINE OPERATION...
Page 50: ......
Page 51: ...1 1 CHAPTER 1 CHAPTER 1 REGULAR MAINTENANCE...
Page 167: ...2 2 CHAPTER 2 CHAPTER 2 TROUBLESHOOTING...
Page 181: ...181 ZERO POINT RETURN COMMAND ALARM TRIGGERED X X Axis Z Z Axis Y Y Axis...
Page 232: ......
Page 240: ......
Page 242: ......