LUBRICATING UNIT ALARMS
9-2
༁໙บʰʕʍʒɁӦͽᆬᝓ
Checking Lubricating Unit Operation
༁໙บʰʕʍʒ٢ӌႱࢠɁՁىȟ༁໙บʰʕʍʒȾȕɞȞǾ
ɑȲɂᥓከȾȕɞȞɥ༁໙บʰʕʍʒɁӦͽᆬᝓɥᚐșȦȻ
ȾɛȶȹᝩɌɑȬǿ
Check whether the cause of the abnormal pressure in the
lubricating unit is in the lubricating unit or piping by checking
the lubricating unit operation.
ᴹਖ਼ᬲᴻ
<Procedure>
1)
ʳɮʽʟɭʵʉɁվҋᥓከɥ۶Ȭǿ
1)
Remove the line filter discharge piping.
2)
ڋɔಃȺʳɮʽʟɭʵʉɁվҋՠɥᩐȫɞǿ
2)
Place a plug over the line filter discharge outlet.
3)
ਖ਼Ӧͽ႕ᬂ˨Ⱥ
‘
༁໙บվҋ
’
ɥ
‘
ɴʽ
’
ȾȪȹǾ
10
ᇽ
ሌ࣊༁໙บʧʽʡɥͽӦȨȮɞǿ
3)
To operate the lubricating pump for about 10 seconds, set
‘FORCED LUBRICANT DISCHARGE’ to ‘ON’ on the
manual operation screen.
1
ᝊȪȗͽศȾȷȗȹɂҝёൡಽͽᝢం
“
ਖ਼Ӧͽ
႕ᬂ
”
1
For detailed operation instructions, refer to the separate
volume, OPERATION MANUAL “Manual Operation Screen”.
2
าᜤ
2
NOTE
1.
٢ӌɁᦉȟ፲Ɂʨ˂ɹɑȺ˨ȟɞɛșȽɜ༁໙บʰʕʍʒ
ɂඩࢠȺȬǿ˨ȟɜȽȗȻȠɂ༁໙บʰʕʍʒɁႱࢠȟᐎț
ɜɟɑȬǿ
1. If the pressure gage stylus reaches the green mark on the line
filter meter, the lubricating unit is normal. If not, the cause of
the alarm is a lubricating unit malfunction.
2.
Ȧɟ͏᪃ɁߦѿศȾȷȗȹɂ
2. Refer to “‘EX0562 (LUBRICANT PRESSURE LOW)’”
(page 195) recovery sequence for further countermeasures.
9-3
༁໙บʰʕʍʒᥓከюɁɲɬȠ
Lubricating Unit Air Removal
ᴹਖ਼ᬲᴷ༁໙บʰʕʍʒɁґᜓᴬ๎ɥᚐȶȲऻᴻ
<Procedure: After Disassembling/Cleaning Lubricating
Unit Relief Valve>
1)
ጸɒȹȲʴʴ˂ʟʚʵʠɥʧʽʡȾɝ͇Ȥɞǿ
1)
Mount the reassembled relief valve on the pump.
2)
ʳɮʽʟɭʵʉɁվҋᥓከɥ۶Ȭǿ
2)
Remove the line filter discharge piping.
3)
ɿɹʁʱʽʟɭʵʉȟʉʽɹюɁ༁໙บȾɞৰȾȬ
ɞǿ
3)
Soak the suction filter in lubricant in the tank.
4)
ਖ਼Ӧͽ႕ᬂ˨Ⱥ
‘
༁໙บվҋ
’
ɥ
‘
ɴʽ
’
ȾȪȹǾ༁໙บ
ʧʽʡɥͽӦȨȮǾɲɬȠɥᚐșǿ
4)
Set ‘FORCED LUBRICANT DISCHARGE’ to ‘ON’ on the
manual operation screen. The lubricating pump will bleed
air from the piping.
5)
ɲɬȠީ̘ऻǾڋɔಃȺʳɮʽʟɭʵʉɁվҋՠɥᩐȫ
ɞǿ
5)
After air removal is completed, insert a plug into the pump
discharge outlet.
ᴹਖ਼ᬲᴷ༁໙บʰʕʍʒ٢ӌႱࢠɁՁىȟᥓከȾȕɞȻȠᴻ
<Procedure: When Abnormal Pressure in the Lubricating
Unit is Triggered by Piping Abnormality>
1)
ਖ਼Ӧͽ႕ᬂ˨Ⱥ
‘
༁໙บվҋ
’
ɥ
‘
ɴʽ
’
ȾȪȹǾ
10
ᇽ
ሌ࣊༁໙บʧʽʡɥͽӦȨȮɞǿ
1)
To operate the lubricating pump for about 10 seconds, set
‘FORCED LUBRICANT DISCHARGE’ to ‘ON’ on the
manual operation screen.
2)
ɥ
3
ᵻ
4
وᎱɝᣌȬǿ
2)
Repeat step
above 3 or 4 times at intervals.
3)
༁໙บɁ٢ӌȟ
1.0
ᵻ
1.2 MPa
ɑȺ˨ȟɞȦȻɥᆬᝓȬ
ɞǿ
3)
Confirm that the lubricant pressure rises to between
1.0 MPa - 1.2 MPa.
9-4
༁໙บʰʕʍʒʴʴ˂ʟʚʵʠɁґᜓᴬ๎
Lubricating Unit Relief Valve Disassembly/Cleaning
ʴʴ˂ʟʚʵʠɁӦͽ˪ᓦȟ༁໙บʰʕʍʒ٢ӌႱࢠɁՁى
ȻȪȹᐎțɜɟɞȻȠɂǾʴʴ˂ʟʚʵʠɁґᜓᴬ๎ɥᚐ
ȗɑȬǿ
If a lubricating unit abnormal pressure is caused by a relief
valve malfunction, disassemble and clean the relief valve
according to the following procedure.
Summary of Contents for NL1500/500
Page 8: ......
Page 9: ...CONTENTS FOR SAFE MACHINE OPERATION REGULAR MAINTENANCE TROUBLESHOOTING INDEX...
Page 10: ......
Page 19: ...FOR SAFE MACHINE OPERATION...
Page 50: ......
Page 51: ...1 1 CHAPTER 1 CHAPTER 1 REGULAR MAINTENANCE...
Page 167: ...2 2 CHAPTER 2 CHAPTER 2 TROUBLESHOOTING...
Page 181: ...181 ZERO POINT RETURN COMMAND ALARM TRIGGERED X X Axis Z Z Axis Y Y Axis...
Page 232: ......
Page 240: ......
Page 242: ......