25
REP 3.19 PCB MD6DC
Removal
Remove Infeed cover according to CRI 2.2.
Remove all connectors from the PCB.
Squeeze the barbs of the pins and remove PCB.
Replacement
Reinstall PCB.
Reconnect all connectors to the PCB.
Make sure all DIP-switches are set to OFF according to picture.
NOTE:
Make sure to download the latest software, according to EDI 4.1.
Reinstall Infeed cover.
1.
2.
3.
1.
2.
3.
4.
P5
P4
P11
P3
P2
P13
P14
ON
CAUTION
ESD Hazard! ESD (Electrostatic Discharge) can cause software crashes,
data and/or communications problems. Failure to use proper ESD pro-
cedures will cause damage to electronic components (example: PCBs).
ESD problems can be minimized by maintaining all machine ground con-
nections, ensuring the proper handling of circuit boards and sensors. Use
ESD protection when working near PCBs. Failure to use ESD protection is
likely to result in a PCB failure.