16
REP 3.10 HOME POSITION STAPLER MOTOR M1
Purpose
Switch SW7 stops the Stapler motor at home position. There are two springs that
holds the Stapler yoke in top position when Stapler motor is in home position.
Switch off the main power switch and disconnect the power cord.
Remove Front and Infeed cover, according to CRI 2.1 and 2.2.
Empty the Stapler magazines.
Turn the Stapler motor crank manually until the motor crank arm is aligned with
the plastic crank arm.
1.
2.
3.
4.
Adjustment
Locate Switch SW7 positioned on side frame operator side.
Loosen the screws (1).
Position SW7 so that the gap is 0.5 - 2.0 mm and tighten the screws (1).
1.
2.
Stapler motor
Plastic crank arm
Motor crank
1
SW7
0.5-2.0 mm
Summary of Contents for Plockmatic BM 60
Page 2: ...BOOKLET MAKER BM 60 61 SERVICE MANUAL 3 October 2006 Part no 60243 ...
Page 3: ......
Page 27: ...26 ...
Page 36: ......
Page 37: ......