5
Warning:
The chimney must be constructed according to regulation stan-
dards.
For an external installation, use an insulated chimney flue that can
be inspected on the curves. The outdoor section of the chimney
flue must be insulated. Use only stainless steel tubes. Do not use
synthetic materials or aluminium.
All sections of the fume exhaust must be accessible for inspections
and internal cleaning.
In the internal section of the flue, provide one or more measuring
points for emission control. The measuring points must be sealed.
The appliance works in depression at the smoke outlet and is equi-
pped with a fan for the expulsion of fumes.
The minimum draft is indicated in the table of technical data.
Failure to comply with the above specifications will void the war-
ranty.
Installation of the remote room thermostat
The boiler allow for the installation of a on/off remote thermostat. The
connection for the remote thermostat is located on the back of the boiler
straight under the power connector, it has a two pin connector coupling
with two buttons, one black and one red. The connection to the thermo-
stat assures the function that the boiler can go into Modulation.
Filling the system
Before installing the hydro stove it is recommended to carefully wash out
all the tubes of the system in order to remove any debris that may affect
the proper function of the appliance.
Once all plumbing connections have been completed, the system must
be filled with water. Open all vents. Open the filling valve and check for
any leaks. Close the tap and the vent valves. Start the pump several
times to remove any eventual air pockets.
Warning:
The exhaust of the safety valve must be connected to a drain
so it can flush out incoming hot water.
INTERNAL CHIMNEY FLUE
CORRECT
INSTALLATION
PROTECTION
CAP
INSULATED
CHIMNEY
FLUE
NOT
INSULATED
CHIMNEY
“
T
”
WITH
INSPECTION
CAP
CHIMNEY FLUE THROUGH OUTSIDE WALL
CORRECT
INSTALLATION
PROTECTION
CAP
INSULATED
CHIMNEY
FLUE
INSULATED
“
T
”
WITH
INSPECTION
CAP
NOT
INSULATED
CHIMNEY
FLUE
“
T
”
WITH
INSPECTION CAP
“
T
”
WITH
INSPECTION
CAP
EXTERNAL FREE CHIMNEY FLUE
IMPROPER
INSTALLATION
EN