15
Storage Tank Thermostat
(Only with configuration 2,3,4)
It activates only if one of the hydraulic configurations is selected. It al-
lows you to change the temperature of the thermostat connected to a
Storage Tank (see
HYDRAULIC SYSTEM MANAGEMENT
on page 17).
•
Enter the menu by pressing P3, use the keys P4 and P6 to select
Storage Tank Thermostat and enter by pressing P3. Press P3 to
enter edit mode, select the desired mode using the keys P4 and P6
then save the setting by pressing P3 again. Press P1 to exit the
menu.
Thermostats
This item allows you to set the maximum water temperature in the boiler.
Once this value has been reached, the system switches to Modulation
mode.
•
Press P3 to access the first page of the Menu, which consists of the
User Menu.
•
Use the keys P4 and P6 to select Thermostats and press P3 to
enter. Press P3 again to enter edit mode (the
“
Set
”
field flashes),
use the keys P4 and P6 to increase or decrease the value and
confirm the setting by pressing P3. Press P1 to exit the menu.
Chrono
This menu allows you to set the switch on and switch off
time slots for the stove.
•
Enter the Chrono menu and select between the two submenus:
Modality or Program.
Power
Chrono
Thermostats
Boiler
Set: 65
ORDER
MENU
1
Settings
2
Service
3
Display
4
System Menu
The menus are the following:
Simply press P3 to enter the following Menu
Power
After selecting Power, it is possible to set the combustion power.
Pellet
Set: 5
ORDER
MENU
1
Power
2
Thermostats
3
Chrono
Press and hold for 3 seconds P3 to enter the following Menu
Boiler
Storage Tank Thermostat
Storage Tank Thermostat
Set: 60
Program
Modality
Modality
The selected item is highlighted.
•
Enter edit mode by pressing P3, set
“
ON
-
OFF
”
by pressing P2, se-
lect the desired item by using the keys P4 and P6 and save the new
setting by pressing P3. The system will exit the menu automatucally.
If it is disabled, none of the programmed switch on times can be activa-
ted.
OFF
Weekly
senai
Weekend
Daily
EN