background image

MN00178

1359

INSTALLATION PROCEDURES – ELECTRICAL:

General Comments

The interface cable between the computer and integrated camera system is important to the reliable operation of any motorized instrument positioning system.  Selection 
of the type of cable, the size (AWG), the number of conductors required, grounding techniques, special consideration for wiring to the devices mounted on the pan/tilt unit, 
plug connections and the pan/tilt options are the topics covered in this Section.

Wire Selection

Careful consideration should be given to the type of cable utilized in order to achieve long-term reliability and avoid costly system modifications.  The type of cable instal-
lation, such as, underground, overhead, pole mounted generally requires cable designed for the specific application.  In addition, the wire may have to be run in conduit.  
Check your local electrical code.  Adequate wire size insures that sufficient voltage will reach the pan/tilt motors, which will provide the required torque to move the camera.  
One factor that influence the wire size is the distance between the power supply and the pan/tilt unit.  The current draw is approximately 5.625 amps (135 W @ 24VDC) 
with a dual camera system.  Size the connecting wires to minimize voltage drop to the positioner based on distance from the power source. 

Mating Connector Installations

Pan / Tilt Site - A mating connector is provided.  Carefully solder the cable leads to the Pan / Tilt mating receptacle pins.  Refer to the appropriate schematic and / or  
connector diagram.  

Connector Pin 

Signal Description          

 

Conductor used on Test Cable

A  Input 

Power, 

+10-30 

VDC 

 Red 

 

  18 

AWG

B  Input 

Power, 

VDC 

(return) 

 Black 

  18 

AWG

L  Chassis 

Ground 

  Green 

  18 

AWG

N  Aux 

Power, 

24VDC 

  Orange 

 

  18 

AWG

R  Aux 

Power, 

VDC 

(return) 

 Brown 

  18 

AWG 

 

Cam 1, Tx+ (IP, pin 1 of RJ45)   

White / Orange  

 

(Cat 5E)

 

Cam 1, Tx-, (IP, pin 2 of RJ45) 

 

Orange    

 

(Cat 5E) 

  

Cam 1, Rx+, (IP, pin 3 of RJ45)    

White / Green 

 

(Cat 5E) 

 

Cam 1, Rx-, (IP, pin 6 of RJ45)    

Green 

 

 

(Cat 5E) 

 

Cam 2, Tx+ (IP, pin 1 of RJ45)   

White / Orange  

 

(Cat 5E)

 

Cam 2, Tx-, (IP, pin 2 of RJ45) 

 

Orange    

 

(Cat 5E)

 

Cam 2, Rx+, (IP, pin 3 of RJ45)    

White / Green 

 

(Cat 5E)

 

Cam 2, Rx-, (IP, pin 6 of RJ45)    

Green 

 

 

(Cat 5E)

Aux power is used for models with illuminators.  Connections are not required if you do not have an illuminator.

PINOUTS SHOWN FOR REFERENCE ONLY - PLEASE REFER TO THE SCHEMATIC THAT CAME WITH YOUR PRODUCT

INSTALLING / UNINSTALLING  CAMERA ASSEMBLY

The GeminEye system should have arrived with the camera systems installed. In the event that a camera system must be removed or reinstalled, please follow these instructions: 

To detach a camera module:
1.  

Turn off power to the system. 

2.  

Remove the locking screw at the rear of the camera module on the stainless steel plate. The screw has a 1/4" head. 

3.  

Slide the stainless steel locking plate toward the rear. 

4.  

Separate the camera from the positioner by gently pulling outward.  Use caution to not pull on the connector once the module pulls away. 

5.  

Disconnect the electrical cable by turning the connector sleeve counter clockwise. 

To attach the camera module to the GeminEye, reverse the above process:

1. 

Turn off power, then connect camera cable to mating plug in camera module.

2. 

Stainless steel locking plate must be retracted in direction shown.

3. 

Camera module is oriented for the hole in the locking plate to line up with the hole in the camera module.  Apply pressure to compress the sealing gasket by  

 

pressing the camera housing toward the GeminEye center section. Engage the locking plate by sliding toward the pivot axis of the camera housing. Install  

 

retaining screw at rear of locking plate.

4. 

For daylight cameras, clean front window glass before installing GeminEye system.

5. 

Test total camera, lens, positioner functions before installing on mount.

INTERNAL ACCESS  & ADJUSTMENT

NOTE:  Normal operation and maintenance do not require opening the unit. The belt drive system requires no lubrication, and the bearings are lubricated and sealed. No 
opening of the positioner for adjustment or inspection is required.  

Summary of Contents for EXO GeminEye

Page 1: ...60062 1 847 498 0700 Fax 1 847 498 1258 www moogS3 com EXO GeminEye HD Camera System QPT LT Positioner Installation and Operation Instructions Before attempting to connect or operate this product plea...

Page 2: ...ation 12 Application 12 System Status 13 Configuration 14 Configuration Date Time 14 Configuration Network 15 Configuration Network DHCP 15 Configuration Network Host Name Configuration NPT 15 Configu...

Page 3: ...sitioner There is no requirement for lubrication or periodic inspection A quick release system allows removing the camera housing s for quick replacement with plug play capability The camera housings...

Page 4: ...Internal fixed stops adjustable soft limits Repeatability 0 25 Material Housings Aluminum Hardware Stainless Steel Exterior Color Finish White Marine Powder Coated other colors custom colors private l...

Page 5: ...in all packing material until claim is settled Check the box contents for 1 Integrated Camera System 1 mating connector 1 test cable 1 basic test software manuals CD00556 and 1 system schematic If any...

Page 6: ...re metric millimeters while other dimensions are in inches A selection of QuickSet Mounts are available for wall pedestal corner and pole mounting When used with the QuickSet wall mount bracket these...

Page 7: ...reen Cat 5E X Cam 1 Rx IP pin 6 of RJ45 Green Cat 5E Y Cam 2 Tx IP pin 1 of RJ45 White Orange Cat 5E Z Cam 2 Tx IP pin 2 of RJ45 Orange Cat 5E a Cam 2 Rx IP pin 3 of RJ45 White Green Cat 5E b Cam 2 Rx...

Page 8: ...trol board processes all communication and position information OPTO POSITION DETECTORS There are 2 detection circuits used for detecting position and dynamic re calibration The pan uses a 4 channel o...

Page 9: ...e the second way which is the Unicast Discovery The Unicast Discovery can be configured by using the Unicast Discovery configuration form This configuration form is available via the Admin Unicast Dis...

Page 10: ...ral small ranges of IP addresses The ping timeout option can be increased for a high latency network The MCT will display as many devices as it discovers on the network If no DHCP server was able to a...

Page 11: ...IP information is set the Silverlight web application served by the EXO Camera can be launched from the MDT or directly in your web browser by typing the device s IP address in the address bar You can...

Page 12: ...n Application When entering the Web Application the following window will be displayed You will be asked a username and password The default User name and Password is admin To reset the user name and...

Page 13: ...3 Maintenance 3 0 0 4 Live Viewer 4 0 0 5 Recording 5 0 0 Status Window Main Menu Tabs Upon successfully logging into the web interface a welcome screen will be displayed The welcome screen shows gene...

Page 14: ...y a custom name this name can be used by third party software to display a selected name for the device Configuration Date Time Under the Configuration section select the Date Time tab to perform the...

Page 15: ...static IP information Configure an NTP server to allow the device to automatically update its internal clock using an NTP server Configuration Network Host Name Configuration NPT NPT Server use when d...

Page 16: ...boot time Milestone VMS will link through the PSIA API Note ONVIF is standard built in and does not require activation If using ONVIF you do not need to select an API Set Bonjour discovery protocol s...

Page 17: ...to 15fps Configure video compression parameters for any of the three available codec instances Primary H 264 Secondary H 264 and MJPEG Most VMS software solutions will interact with these parameters...

Page 18: ...you can set the minimum and maximum to the same value The lower the value the better the quality will be VBR Aggressiveness This parameter allows you to specify if the codec should take into account t...

Page 19: ...are 2 available strings Text blocks Select string Select string Size For string position click mouse inside string position box Text bar will appear on video image If you wish to relocate simply clic...

Page 20: ...ensitivity and Thresholds Press Save button to store information You can select up to 4 separate Motion windows Frame count Number of frames required to trigger motion Sensitivity No sensitivity 100 M...

Page 21: ...Under the Configuration section select the Audio Out tab to perform the following operations Configure audio output parameters Configure a point to point audio connection for receiving a persistent a...

Page 22: ...assphrase is made available for additional security Manage user accounts which have access to the device User Roles Administrator All is available Super user All is available except the user managemen...

Page 23: ...rovided by Moog 4 You will see the following messages indicating the status of the update Firmware upload in progress 100 Lasts around 95 seconds Firmware uploaded Saving to internal storage 0 Lasts a...

Page 24: ...Live Camera View Start and Stop Recording Pan Tilt and Camera Control Setting Presets Adjust View Scale To enable live you must activate by pressing the Play button To adjust viewing scale for 1024 x...

Page 25: ...tion use buttons to update Iris Zoom and Focus Preset Functions First Select Preset No Then position Camera and lens to desired position o Press Set to save Preset For additional presets repeat proces...

Page 26: ...wer firmware versions from the MCT The batch firmware update works by starting a firmware update session Only one session at time is allowed and only 20 devices can be selected by session From the MDT...

Page 27: ...Update Session window shows the progress of the firmware update This window can be closed at any moment without losing the current session If closed the progress of the current session can be followed...

Page 28: ...us sections of the same web page Destination IP Address where to send the video This is usually the address of a Decoder The destination can also be a multicast group address DNS names are not yet sup...

Reviews: