H*38SVO-ST Outdoor Gas Fireplace
Page 6
XG0817 - 080311
Installation
Section 2: Framing
Figure 3.
Framing dimensions (without Optional surround). Must be back-
framed as shown in Figure 2a below.
Installing The Fireplace Shell
The fireplace may be installed in a location that maintains clearances to
ALL exterior furniture, appliances and other exterior equipment. Safety,
as well as efficiency of operation, must be considered when selecting
the fireplace location. Try to select a location that does not interfere with
foot traffic, has adequate ventilation, and offers an accessible pathway
for ventilated gasses.
Backframe Min. 38"
both sides Typical
41"
Surrounding construction
(bottom, sides and top) must
be non-combustible materials,
metal studs, concrete board
and concrete, brick, or stone.
Existing Co
mbustible Stru
ct
ur
e
40”
41”
23 7/8”
38”
36”
Combustible
materials
Backframe Min. 38"
both sides Typical
41"
Surrounding construction
(bottom, sides and top) must
be non-combustible materials,
metal studs, concrete board
and concrete, brick, or stone.
1" clearance
to corners only
1” Clearance to
combustibles to sides
ot Unit
The fireplace dimensions with the Optional Stainless steel cover, shown
below. (Note: This model is intended as a stand-alone).
Top View
Front View
25⅛”
40⅛" Width
25¾"
Opening
37⅝"
40⅛" Width
6¾"
5¼"
35⅜" Opening
Framing
(stand-alone)
:
For Fireplace without the Optional Stainless steel
surround.
Figure 2.
Fireplace dimensions with insulation jacket