background image

H*38SVO-ST Outdoor Gas Fireplace

Page 17

XG0817 - 080311

Appendix

Appendix B Warranty:

The Warranty

The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo fireplace, 

there is a ten-year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control 

valve, fibre logs and Power Vent Module. The Glass, plated / painted finishes, and refractory lining are exempt from the warranty.

Remedy And Exclusions

The coverage of this Warranty is limited to all components of the Gas Appliance manufactured by The Companies.
This Warranty only covers Montigo Gas Appliances installed in the United States or Canada.
If the components of the Gas Appliance covered by this Warranty are found to be defective within the time frame stated (see The Companies right of investigation 

outlined below). The Companies will, at its option, replace or repair defective components of the Gas Appliance manufactured by The Companies at no charge, 

and will also pay for reasonable labour costs incurred in replacing or repairing components. If repair or replacement is not commercially practical, The Companies 

will, at its option, refund the purchase price of the Montigo Gas Appliance. 
This Warranty covers only parts and labour as provided above. In no case shall The Companies be responsible for materials, components, or construction which 

are not manufactured or supplied by The Companies, or for the labour necessary to install, repair or remove such materials, components or construction. All 

replacement or repair components will be shipped F.O.B. the nearest The Companies factory. 

Qualifications To The Warranty

The Gas Appliance Warranty outlined above is further subject to the following qualifications:
(1)  The Gas Appliance must be installed in accordance with The Companies installation instructions and local building codes. The Warranty on this Montigo 

Gas Appliance covers only the component parts manufactured by The Companies. The use of components manufactured by others with this Montigo Gas 

Appliance could create serious safety hazards, may result in the denial of certification by recognized national safety agencies, and could be in violation of 

local building codes. This warranty does not cover any damages occurring from the use of any components not manufactured or supplied by The Companies

(2)  The Montigo Gas Appliance must be subjected to normal use. The Gas Appliances are designed to burn gas only. Burning conventional fireplace fuels such 

as wood, coal or any other solid fuel will cause damage to the Gas Appliance, will produce excessive temperatures and will result in a fire hazard.

Limitations On Liability

It is expressly agreed and understood that The Companies sole obligation, and purchaser's exclusive remedy under this Warranty, under any other warranty, 

expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above.
In no event shall The Companies be responsible for any incidental or consequential damages caused by defects in its products, whether such damage occurs 

or is discovered before or after replacement or repair, and whether or not such damage is caused by The Companies negligence. Some states do not allow the 

exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of any implied warranty 

with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty 

lasts, so the above may not apply to you.

Investigation Of Claims Against Warranty

The Companies reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement.

The Companies Are Not Responsible For Work Done Without Written Consent

The Companies shall in no event be responsible for any warranty work done without first obtaining The Companies written consent.

Dealers Have No Authority To Alter This Warranty

The Companies employees and dealers have no authority to make any warranties nor to authorize any remedies in addition to or inconsistent with those stated above.

How To Register A Claim Against Warranty

In order for any claim under this Warranty to be valid, The Companies must be notified of the claimed defect in writing or by telephone, as soon as reasonably 

possible after the defect is discovered. Claims against this Warranty in writing should include the date of installation, and a description of the defect.

Other Rights

This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

NOTE:

 

The Companies

 as stated above refer to - Canadian Heating Products Inc. and/or Montigo Del Ray Corp.

Canadian Heating Products Inc. and/or Montigo DelRay Corp. reserves the right to make changes at any time, without notice, in design, materials, 

specifications, prices and also to discontinue colors, styles and products.

Summary of Contents for H38VO-ST

Page 1: ...e or any other flammable vapors and liquids in the vicinity of this or any other gas burning appliance A fire or explosion my occur causing serious injury property damage or even death WARNING Installer Leave this manual with the appliance Do not remove Consumer Retain this manual for maintenance and future reference Do not Discard NOTICE XG0817 080311 WARNING FOR OUTDOOR USE ONLY WARNING CARBON M...

Page 2: ...Wiring 8 Honeywell gas control and pilot 8 Section 5 Installing the Gas Line 9 Section 5 1 Fuel Conversion 9 Section 5 2 Gas Pressure 9 Section 5 3 Gas Connection 9 Section 6 N A Section 7 Installing and Removing the Door 10 Section 8 Installing the Accessories 11 14 Installing the H34VO Log Set 11 Installing the H38VO Log Set 12 Installing the H42VO Log Set 13 Installing the HL38VO Firestones 14 ...

Page 3: ...nual intended to ensure your safety This manual covers installation operation and maintenance Lighting operation and care of this fireplace can be easily performed by the homeowner All installation and service work should be performed by a qualified or licensed installer plumber or gas fitter as certified by the state province region or governing body where the fireplace is being installed Thisins...

Page 4: ...etic field Optical radiation Non ionizing radiation Radiation Hazardous to the Environment Danger of harming your hands Irritant Cutting Watch your step Slippery floor High temperatures Glass hazard Danger of suffocation High voltage Toxic Flammable materials Corrosive Fork lift trucks Danger overhead crane Explosion risk Oxidising Danger of death Biohazard Laser Radiation Danger of entrapment Hot...

Page 5: ... path for Direct Vent installation 41 Shaded area non combustible framing Both wallsTypical May not be exactly as shown Backframe Min 38 both sides Typical 41 Surrounding construction bottom sides and top must be non combustible materials metal studs concrete board and concrete brick or stone Top View Front View Side View 36 Height 24 24 36 Width 25 Opening 36 Width 6 5 35 Opening 1 1 1 41 Shaded ...

Page 6: ...ith foot traffic has adequate ventilation and offers an accessible pathway for ventilated gasses Backframe Min 38 both sides Typical Surrounding construction bottom sides and top must be non combustible materials metal studs concrete board and concrete brick or stone 40 41 23 7 8 38 36 Combustible materials 1 clearance to corners only 1 Clearance to combustibles to sides ot Unit The fireplace dime...

Page 7: ... materials must be used in construction of the enclosure top bottom and sides Steel studs in combination with concrete rock or stone finishing materials are acceptable See Figures 3 4 and 5 Figure 4 Back framing dimensions without Optional surround Figure 5 Framing dimensions without Optional surround Distance from Existing Structures Please follow Appendix A Termination locations when considering...

Page 8: ...switch The valve generates its own power on a millivolt circuit Use only low voltage wire and DO NOT connect any external power to it Refer to Figure 4 for wiring requirements Note The switch location must not exceed 30 from the fireplace Figure 7 Wiring for the H38SVO Honeywell gas control and pilot Figure 8 Standing Pilot Diagram Honeywell Q3450 Pilot Assembly Pilot Electrical Harness Connector ...

Page 9: ...pproved for use by the state province or other governing body in which the fireplace is being installed Section 5 3 GAS CONNECTION See Figure 5 below for location of gas line access Flexible gas connectors must not exceed 3 feet in length unless allowable within local regulations Connect incoming gas line to the 1 2 or 3 8 gas inlet port Purge all air out of gas line Checkapplianceconnection valve...

Page 10: ...aintenance or cleaning Install in reverse order Installed Gas Valve Cover Finger Holes Remove the Horizontal Access Panel To install the door hook the top edge of the door frame into place Lower thedoorintopositionandfollowthepreviousstepsshowninreverseorder Installing the Door 2 Step 5 Ensure the tool is firmly in the lower end of the slot as shown Then pull toward you Caution hold the tool secur...

Page 11: ...re the logs C which are placed diagonally as shown in Figure 24d The last Logs D are then mounted on top of logs A as shown in Figure 11e WARNING If logs are not placed properly excessive sooting will result Figure 11d Log Installation Place Logs C on top of Logs A Indentations on top of Logs A Figure 11c Place Logs B as shown in front of Right hand A and behind Left hand B Log A Log B Log C Log A...

Page 12: ...ors are removed place the glass beads randomlyacrossthepansurroundingtheburnersasshowninFigure12 NOTE DO NOT Cover burners with beads or the optional rocks as shown in Figure 12 Note Ensure the rocks or beads do not cover the Burners Figure 29 Installation of glass beads L42DF ST WARNING Do not attempt to clean glass when hot Do not clean glass with abrasive materials as any glass etching may caus...

Page 13: ... lower Horizontal access panel with Continuous Pilot with American Flame Electronic Ignition For Your Safety READ BEFORE LIGHTING Lighting Instructions 1 STOP Read the safety information above on this label 2 Lift out the lower Horizontal access panel 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any gas Smell for gas including near the floor If you then s...

Page 14: ...r building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Flip down the lower trim 3 Turn the switch on the gas control to Off 4 Flip up the trim 1 STOP Read the safety information above on this label 2 Flip down the lower trims 3 Turn switch on the gas control to OFF 4 Wait 5 minutes to clear out any gas If you smell g...

Page 15: ...cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water Cleaning When the fireplace is first activated there may be some smoking and a visible film may be left on the glass This is a normal condition and is the result of burning of protective coatings on new metal Glass must be cleaned periodically to remove any film which is a nor...

Page 16: ...etely Figure 34 Pilot Burner If your fireplace still does not operate correctly consult your dealer or the manufacturer All service and repairs should be performed by a qualified agency All spare parts optional fans and optional trim finishes are available from your local dealer or the manufacturer Troubleshooting Troubleshooting The following is a troubleshooting chart of possible problems PROBLE...

Page 17: ...Companies 2 The Montigo Gas Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligat...

Page 18: ...ight of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve...

Page 19: ...H 38SVO ST Outdoor Gas Fireplace Page 19 XG0817 080311 Notes ...

Page 20: ...Ferndale Washington TF 1 800 789 6236 FX 1 866 3000 0927 XG0817 080311 Langley British Columbia TF 1 800 378 3115 FX 1 604 607 6462 H38VO ST Outdoor Residential Gas Fireplace ...

Reviews: