H*38SVO-ST Outdoor Gas Fireplace
Page 7
XG0817 - 080311
Installation
Figure 6. Non-combustible surrounds and sidewall clearances.
Fireplace Facing
When selecting the finish material for your fireplace, it is important to
remember the following:
THE LOWER GAS CONTROL PANEL MUST
NOT BE OBSTRUCTED IN ANY WAY - to do so restricts the air supply
for the control compartments and heat exchanger it also prevents
access for servicing controls.
Decorative facing must not extend past the fireplace opening at all,
because it will interfere with the access to retainers for removal of
glass door.
WARNING!
When this appliance is installed directly on exterior carpeting, tile
or any combustible material other than wood flooring, it must be
installed on a metal or wood panel extending the full width and
depth of the appliance.
When installing this fireplace as shown in Figure 5, the outer shell is not
to be installed. Follow Figures 4,5 (wall installation) and Figure 3 (MIN
size enclosure for patio or other contemporary installation) to frame
around the fireplace chassis.
Note: ONLY Non-combustible materials must be used in construction
of the enclosure. (top, bottom and sides). Steel studs in combination
with concrete, rock, or stone finishing materials, are acceptable. See
Figures 3, 4 and 5.
Figure 4.
Back framing dimensions. (without Optional surround)
Figure 5.
Framing dimensions (without Optional surround). Distance from
Existing Structures. (Please follow Appendix A - Termination locations, when
considering a location for your fireplace).
Backframe Min. 38"
both sides Typical
41"
Surrounding construction
(bottom, sides and top) must
be non-combustible materials,
metal studs, concrete board
and concrete, brick, or stone.
Existing Co
mbustible Stru
ct
ur
e
40”
41”
23 7/8”
38”
36”
Combustible
materials
Backframe Min. 38"
both sides Typical
41"
Surrounding construction
(bottom, sides and top) must
be non-combustible materials,
metal studs, concrete board
and concrete, brick, or stone.
1" clearance
to corners only
1” Clearance to
combustibles to sides
ot Unit
Backframe Min. 38"
both sides Typical
41"
Surrounding construction
(bottom, sides and top) must
be non-combustible materials,
metal studs, concrete board
and concrete, brick, or stone.
Existing Co
mbustible Stru
ct
ur
e
40”
41”
23 7/8”
38”
36”
Combustible
materials
Backframe Min. 38"
both sides Typical
41"
Surrounding construction
(bottom, sides and top) must
be non-combustible materials,
metal studs, concrete board
and concrete, brick, or stone.
1" clearance
to corners only
1” Clearance to
combustibles to sides
ot Unit