6-11
6-11
Electrical servicing
Fan motor relay inspection
Remove the fan motor relay.
Connect the ohmmeter to the fan motor relay connector
terminals.
Connection: Red – Blue
Connect the 12 V battery to the following fan motor relay
terminals.
Connection: Red – Black/Blue
There should be continuity only when the 12 V battery is
connected.
If there is no continuity when the 12 V battery is
connected, replace the fan motor relay.
(1) FAN MOTOR RELAY
Cooling fan system inspection
Fan motor inspection
Remove the fuel tank.
Disconnect the fan motor 2P (Natural) connector.
Directly connect the 12 V battery to the fan motor 2P
(Natural) connector terminals of the fan motor side.
The fan motor is correct when the fan motor operate
when the 12 V battery is connected.
If the fan motor does not operate, replace the fan motor
assembly.
(1) 2P (NATURAL) CONNECTOR
Magnetic engine stop switch inspection
Disconnect the magnetic engine stop switch connectors.
Check the magnetic engine stop switch for continuity.
There should be continuity when the magnetic switch top
part (magnet) is removed.
Replace the switch if it is out of specification.
(1) MAGNETIC ENGINE STOP SWITCH
(2) CONNECTORS
2
1
1
1
Summary of Contents for COTA 301RR 2023
Page 1: ...PGM FI Racing Trial Owner s Manual 2023...
Page 6: ...Labels ED 2ED 3 2 1 6...
Page 7: ...Labels 3ED 4ED 4 2 1 7 3 5...
Page 11: ...Memo Memo...
Page 43: ...Service data 2 20 2 20 1 FUEL FEED HOSE 2 TRANSMISSION BREATHER HOSE 1 2...
Page 63: ...3 20 3 20 Memo...
Page 125: ...4 62 4 62 Memo...
Page 175: ...6 20 6 20 Memo...
Page 179: ...7 6 7 6 Memo...
Page 180: ...Printed in Spain 62NN4TREMH...