6-4
6-4
Electrical servicing
L
L
L
1
2
1
If the resistance is out of specification, measure the
resistance at the ignition pulse generator 2P (Natural)
connector.
If the measured resistance at ECM 32P (Black) connector
is incorrect and the ignition pulse generator 2P (Natural)
connector is correct, check the wire harness.
If the resistance is still out of standard, replace the ignition
pulse generator/stator assembly (page 4-52).
(1) 2P (NATURAL) CONNECTOR
Ignition Pulse Generator Inspection
Check the resistance of the pulse generator power in the
32P (Black) connector (page 6-5).
Connection: White/yellow – Green/yellow
Standard: 85 - 115
(20
˚
C/68
˚
F)
(1) 32P (BLACK) CONNECTOR
(1) WIRE CLAMP
(2) PRIMARY WIRES
(3) BOLTS
(4) IGNITION COIL
Remove the wire clamp.
Disconnect the primary wires from the ignition coil.
Remove the mounting bolts and ignition coil.
Installation is in the reverse order of removal.
Route the spark plug wire properly and secure it with
tiewrap.
1
4
3
3
2
2
1
1
Summary of Contents for COTA 301RR 2023
Page 1: ...PGM FI Racing Trial Owner s Manual 2023...
Page 6: ...Labels ED 2ED 3 2 1 6...
Page 7: ...Labels 3ED 4ED 4 2 1 7 3 5...
Page 11: ...Memo Memo...
Page 43: ...Service data 2 20 2 20 1 FUEL FEED HOSE 2 TRANSMISSION BREATHER HOSE 1 2...
Page 63: ...3 20 3 20 Memo...
Page 125: ...4 62 4 62 Memo...
Page 175: ...6 20 6 20 Memo...
Page 179: ...7 6 7 6 Memo...
Page 180: ...Printed in Spain 62NN4TREMH...