1
INSTALLATION
The Montague gas ranges are manufactured for use with the type of gas indicated on the nameplate.
The Montague heavy duty gas ranges are produced with the best possible material and workmanship.
PROPER INSTALLATION IS ESSENTIAL FOR SAFE AND EFFICIENT TROUBLE-FREE OPERATION.
THE INSTALLATION INSTRUCTIONS CONTAINED HEREIN ARE FOR
THE USE OF QUALIFIED INSTALLATION AND SERVICE PERSONNEL
ONLY. INSTALLATION OR SERVICE BY OTHER THAN QUALIFIED
PERSONNEL MAY RESULT IN DAMAGE TO THE OVEN AND/OR
INJURY TO THE OPERATOR.
Qualified installation personnel are individuals, a firm, corporation or company which either in person,
or through a representative are engaged in, and are responsible for:
A.
The installation or replacement of gas piping or the connection, installation, repair or servicing of
equipment, who is experienced in such work, familiar with all precautions required, and has
complied with all requirements of state or local authorities having jurisdiction. Reference: National
Fuel Gas Code Z223.1, Section 1.4.
B.
The installation of electrical wiring from the electric meter, main control box or service outlet to
the electric appliance. Qualified installation personnel must be experienced in such work, be
familiar with all precautions required and have complied with all requirements of state and local
authorities having jurisdiction. Reference: National Electric Code, ANSI/NFPA No. 70.
READ CAREFULLY AND FOLLOW THESE INSTRUCTIONS
THE RANGE(S) MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, OR
IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL FUEL GAS CODE,
ANSI Z223.1- LATEST ADDENDA, INCLUDING:
1.
The appliance and its individual shutoff valve must be disconnected from
the gas supply piping system during any pressure testing of that system at
test pressures in excess of 1/2 psig. (3.45 kPa).
2.
The appliance must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure testing of
the gas supply piping system at test pressure equal to or less than 1/2 psig.
(3.45 kPa).
PROVISIONS MUST BE MADE FOR ADEQUATE AIR SUPPLY TO THE UNIT.