8
OPERATING INFORMATION FOR THE RANGE HAS BEEN PREPARED FOR
USE BY QUALIFIED AND/OR PROFESSIONAL OPERATING PERSONNEL.
CAUTION
DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION AIR
TO THE RANGE. KEEP THE APPLIANCE AREA FREE AND CLEAR FROM
COMBUSTIBLES.
GAS CONTROLS
IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT MAIN
SHUT OFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS
SUPPLIER FOR SERVICE.
TOP BURNERS-OPEN, HOT TOP AND MANUAL FRYTOP
Check that pilots are burning. Then rotate valve handles counter clockwise to full on, burner will
ignite automatically. Adjust flame height as desired. To shut down, rotate valve handle clockwise to
"OFF" position.
FRY TOP-THERMOSTAT CONTROLLED
Check that pilot(s) are burning. Then push thermostat dial inward and rotate dial counter-clock-
wise to maximum thermsotat setting, burner(s) will ignite automatically. After ignition, turn thermostat
dial to desired setting. To shut down, rotate thermostat dial clockwise to "OFF" position.
OVEN - 136 SERIES
A. Lighting
Turn burner valve to "OFF" position and wait five (5) minutes.
1. Remove burner compartment cover and open pilot access door.
2. Press and hold red button in (Safety Pilot Valve) and apply lighted match to pilot burner.
3. After pilot burner ignites, continue to hold red button depressed for 30 to 45 seconds or until
pilot remains burning when button is released. If pilot goes out, repeat process.
4. Close pilot access door and replace burner compartment cover.
5. Turn burner valve on and rotate thermostat dial counter-clockwise to desired temperature
setting.
6. IN THE EVENT OF PILOT FAILURE, TURN BURNER VALVE CLOCKWISE TO "OFF"
POSITION AND WAIT FIVE (5) MINUTES FOR UNBURNED GAS TO ESCAPE FROM
RANGE.
B
Shut Down
Turn burner valve clockwise to "OFF" position.
SERVICE