background image

23

The Montague Company

1830 Stear

man A

ven

ue

, Ha

y

w

ard, Calif

o

rnia 94545

Item

     Part #

Description

1

.......

04330-3

.........

V

a

lv

e

, T

o

p

 B

u

rner (Nat) Except 1/2 Hot 

T

o

p

1

.......

01003-0

.........

V

a

lv

e

, T

op 

Bur

ner (LP) Except 1/2 Hot 

T

o

p

1

.......

02101-1

.........

V

a

lv

e

T

op Bur

ner (Nat) 1/2 Hot 

T

op Only

1

.......

01002-2

.........

V

a

lv

e

, T

op Burner (LP) 1/2 Hot 

T

op Only

3

.......

02002-8

.........

Handle,

 V

a

lv

e w/Set Scre

w

4

.......

03348-0

.........

V

entur

i, F

ront Bur

n

e

r

4

. 6

, 7

, 8

..

03347-2

.........

Bur

n

e

r, 

F

ront - Complete

5

.......

03350-2

.........

V

entur

i, Rear Bur

ner (Left s

wing sho

wn)

5

, 6

, 7

, 8

..

03349-9

.........

Bur

n

e

r, Rear Left - Complete

5A, 6, 7, 8

03351-0

.........

Bur

n

e

r, Rear Right Complete (not shown)

6

.......

02115-6

.........

Gasket

7

.......

03346-4

.........

Burner Head Only

8

.......

02038-9

.........

Air Mixer

9

.......

01055-3

.........

Pilot V

a

lv

e

1

0

.....

03583-1

.........

Lighter

, Pilot

10, 11, 20

03431-2

.........

Pilot Kit - 12" Section (Less 

V

a

lv

e

)

10, 12, 20

03430-4

.........

Pilot Kit - 18" Section (Less 

V

a

lv

e

)

20, 21, 22

07142-0

.........

P

ilot Kit - 12" -59 Section (Less 

V

a

lv

e

)

1

3

.....

01518-0

.........

P

ilo

t B

ra

c

k

e

t

1

4

.....

03379-0

.........

D

rip T

ra

y

 - 36" Unit

1

4

.....

03378-2

.........

D

rip T

ra

y

 - 24" Unit

1

4

.....

03377-4

.........

D

rip T

ra

y

 - 18" & 12" Unit

1

5

.....

03380-4

.........

D

rip T

ra

y

 Guide

1

6

.....

03498-3

.........

Support, Open Burner 36" Unit

1

6

.....

03530-0

.........

Support, Open Burner 24" Unit

1

6

.....

03531-9

.........

Support, Open Burner 18" Unit

1

6

.....

03532-7

.........

Support, Open Burner 12" Unit

1

7

.....

03480-0

.........

18" 

Open T

o

p

1

8

.....

03580-7

.........

12" 

Open T

o

p

1

9

.....

03482-7

.........

12" Combination -59 

T

op (1/2 Hot 

T

o

p

)

2

2

.....

06232-4

.........

Lighter

, Pilot

2

3

.....

03556-4

.........

B

ra

c

k

e

t, Pi

lot MTG (-59 

T

o

p

)

Monta

gue Hea

vy Duty Gas Rang

e - Open 

T

op Section

12" and 18" 

Wide - 1/2 Open 

T

op 1/2 Hot 

T

op - 12" 

Wide

Summary of Contents for Legend 12 Series

Page 1: ...thoroughly before attempting installation Set up and installation should be performed by qualified installation personnel Keep area around appliances free and clear from combustibles PLEASE RETAIN TH...

Page 2: ...OR DAMAGE If damage is unnoticed until merchandise is unpacked notify transportation company or carrier immediately and file concealed damage claim with them This should be done within fifteen 15 day...

Page 3: ...es having jurisdiction Reference National Fuel Gas Code Z223 1 Section 1 4 B The installation of electrical wiring from the electric meter main control box or service outlet to the electric appliance...

Page 4: ...therwise a subnormal atmospheric pressure will occur which may interfere with burner performance or may extinguish the pilot flame In case of unsatisfactory range performance check with the exhaust fa...

Page 5: ...t to rear and side to side Adjust as follows FLOOR INSTALLATION ON LEGS Adjust by turning foot on adjustable leg CURB INSTALLATION ON LEGS Place shim under the low side This operation is important sin...

Page 6: ...HIGH SHELVES AND SALAMANDER BROILERS Lift high shelf or broiler above the range and slide legs into position See Fig 2 GAS APPLIANCE REGULATOR A GAS APPLIANCE PRESSURE REGULATOR SUITABLE FOR THE BATT...

Page 7: ...ply line be sure that all new piping has been cleaned and purged to prevent any foreign matter from being carried into the controls by the gas In some cases filters or drops are recommend A separate G...

Page 8: ...ase pilot flame Adjust flame to a point where only a trace of yellow tip remains HOT TOP FRY TOP Each pilot is controlled by a pilot valve Turn adjusting screw until pilot flame is 1 2 high BURNER ADJ...

Page 9: ...ould require no further adjustment if the gas manifold pressure is correct THE BYPASS FLAME MUST BE RECHECKED WHEN PERFORMING CHECKOUT OF RANGE PRIOR TO PLACING EQUIPMENT IN SERVICE THE BYPASS MUST BE...

Page 10: ...r clock wise to maximum thermsotat setting burner s will ignite automatically After ignition turn thermostat dial to desired setting To shut down rotate thermostat dial clockwise to OFF position OVEN...

Page 11: ...to hold red button depressed for 30 to 45 seconds or until pilot remains burning when button is released If pilot goes out repeat process 5 If the pilot burner is unable to be lit with the piezo igni...

Page 12: ...dinary soap solution Dry thoroughly with a clean cloth To remove grease and food splatter or condensed vapors that have baked on the equipment apply cleanser to a damp cloth or sponge and rub cleanser...

Page 13: ...d wash drip pan under burners Brush burner head weekly with a stiff wire brush and clean clogged ports with stiff wire or ice pick Excessive grease build up may be removed from burners by soaking in a...

Page 14: ...magnetic coil under the red button and holds valve open permitting gas to flow to main burner and pilot without holding pressure on red button In the event of pilot failure the flow of electricity wil...

Page 15: ...ecision instrument carefully made and properly calibrated i e the dial is properly set at the factory to control temperatures accurately It should control temperatures for the proper cooking of food w...

Page 16: ...tically turn down to this bypass flame when the temperature set on the dial is attained Special care should be taken to see that the thermostat bulb is in its proper place and no part of the capillary...

Page 17: ...See Adjustment of Bypass Minimum Burner Flame before recalibrating this thermostat HOT CHECK METHOD 1 Place reliable thermometer in center of the top of the fry top over the thermal bulb 2 Set Dial A...

Page 18: ...USTED ADJUSTMENT OF BYPASS MINIMUM BURNER FLAME 136 SERIES Enough gas must be bypassed through the heat control to keep the entire burner lit while in use The control regulates the flame from high to...

Page 19: ...contact with the ends of the screw clearance slots in the calibration plate remove the screws and after turning the calibration plate to the proper location reassemble screws in the other tapped hole...

Page 20: ...T BE SET CAREFULLY AND ACCURATELY AS FOLLOWS 1 Light burners and turn Dial A counterclockwise and to a point midway between the Gas On mark and next graduation to the right of it shown by X If the bur...

Page 21: ...holding calibration stem C in firmly with screwdriver turn dial until it is set at the actual oven temperature as shown by your test instrument or thermometer Release pressure on calibration stem Rep...

Page 22: ...r u t a N 8 4 2 4 8 4 2 5 7 3 6 3 2 3 8 4 C W 0 0 1 s a G e n a p o r P 6 5 5 5 0 5 5 5 5 5 6 5 9 4 7 4 1 5 5 5 5 5 A B D C F E D Orifice Size Chart Drill Size FRONT REAR A FRY TOP B 12 HOT TOP C 18 H...

Page 23: ...21 The Montague Company 1830 Stearman Avenue Hayward California 94545 Montague 124 136 Series Heavy Duty Range Parts List...

Page 24: ...XLB Series Only Item Part Description 1 31081 6 Door Panel Ext S S 136XLB 1 31679 2 Door Panel Ext S S 124 Series w o nameplate 2 32536 8 Door Panel Int Porcelain 124 Series 2 31680 6 Door Panel Int O...

Page 25: ...ad Only 8 02038 9 Air Mixer 9 01055 3 Pilot Valve 10 03583 1 Lighter Pilot 10 11 20 03431 2 Pilot Kit 12 Section Less Valve 10 12 20 03430 4 Pilot Kit 18 Section Less Valve 20 21 22 07142 0 Pilot Kit...

Page 26: ...635 7 Baffle Burners Cast Iron 12 Manifold Shield W Stops 13 03560 2 Insulated Side Shield 14 01738 8 Hot Top 12 Section Montague Heavy Duty Gas Range Hot Top Section Even Heat 12 and 18 Wide Item Par...

Page 27: ...Assy 36 Unit 6 04414 8 Baffle Air Assy 18 Unit 7 04281 1 Burner Brick Support 36 Unit 7 04298 6 Burner Brick Support 18 Unit 8 01764 7 Brick 1 1 4 x 8 x 13 9 03356 1 Burner 18 Hot Top Complete Right S...

Page 28: ...d in accordance with all local codes or in the absence of local codes with the current National Fuel Gas Code Z223 1 2 Installed under a properly designed and operating exhaust hood 3 Connected to the...

Page 29: ...TANT When ordering parts to eliminate mistakes and facilitate delivery always give the following information Serial No _________________________________________ Model No ______________________________...