14
ADJUSTMENT OF BYPASS (MINIMUM BURNER) FLAME
This is the flame which must be maintained on the burners when the fry top has reached the
temperature set on the dial. Enough gas must be bypassed by the control to keep the entire burner
lit. The thermostat regulates the flame from high to low in accordance with the fry top temperature
and will automatically turn down to this bypass flame when the temperature set on the dial is attained.
Special care should be taken to see that the thermostat bulb is in its proper place and no part of
the capillary tube is in any flame or heat zone. The fry top plate should never be removed without
first removing the thermostat bulb(s) from beneath the plate. Never allow capillary tube to be kinked
or crushed.
1. Fry Top plate
2. Shield
3. Screw, holding
4. Bracket,support
5. Insulated block
6. Backing plate
7. Sleeving
Thermostat Sensing Bulb Holder Assembly
SERVICE