5.2 Connecting audio sources

Each input channel provides a jack (18) for the 
connection of a microphone or mono audio 
source with line signal level (e . g . mono output 
of a mixer) . The jack is balanced . If the output 
of the audio source is balanced as well, use an 
XLR plug or a 3-pole 6 .3 mm plug for connec-
tion . For an unbalanced output, use a 2-pole 
6 .3 mm  plug .

When a microphone is connected, turn 

the control GAIN (20) of the respective channel 
towards “MIC”; when an audio source with 
line signal level is connected, turn the control 
towards “LINE” . If required, readjust the set-
ting during operation (

 chapter 6, item 4) . 

Phantom power supply:

To activate the 24 V phantom power supply for 
a channel (e . g . when a condenser microphone 
is connected), engage the appropriate button 
PHANTOM POWER (19) . To deactivate the 
phantom power supply, disengage the button . 

ATTENTION

1 .  Only actuate the button when the amplifier 

is switched off (switching noise) .

2 .  Only activate the phantom power supply 

when a phantom-powered audio source 
is connected; audio sources not designed 
for phantom power supply (e . g . micro-
phone with unbalanced output) may be 
damaged .

5.3 Defining the priority

The DIP switches PRIORITY (16) can be used to 
assign different priorities to the channels CH 1, 
CH 2 and CH 3 . The volume of a channel with 
a lower priority will be attenuated as soon as 
a signal is available on a channel with a higher 
priority . Signals of channels with the same pri-
ority will have no effect on each other . Use the 
table (fig . 9) to set the desired priority order 
of the channels .

Use the control MUTE (17) to define the 

level of volume attenuation (left stop = min . 
attenuation, right stop = max . attenuation) .

5.4 Connecting the muting switch

To mute the amplifier, connect a switch (nor-
mally open contact) to the terminals EXT . PRIO . 
(15) .

5.5 Power supply and 

emergency power supply 

1)  To ensure continued operation of the 

amplifier after a mains failure, connect the 
terminals DC INPUT (13) to an emergency 
power supply unit (

 24 V),  e . g .  the  emer-

gency power supply unit PA-24ESP from 
MONACOR .

Notes:

1 .   When 

 24 V is available at the terminals DC 

INPUT, the amplifier will be in operation even 
when the button POWER (9) is disengaged, i . e . 
in case of a mains failure, the button POWER 
will have no effect . When both the emergency 
power supply and the mains power supply are 
available, the button POWER will switch bet-
ween these two power supplies .

2 .  With emergency power supply, the amplifier 

will provide less power than with mains power 
supply .

2)  Finally, first connect the mains cable pro-

vided to the mains jack (10) and then to a 
mains socket (230 V/ 50 Hz) .

6  Setting the Amplifier into 

Operation

WARNING

Never operate the unit without 
the protective cover (12) . Risk of 
electric shock when touching the 
speaker terminals!

To prevent switching noise, always switch on 
the units connected before switching on the 
power amplifier of the PA system and switch 
off the power amplifier before switching off 
the units connected .
1)  To prevent a volume which is too high, turn 

the total volume control MASTER (8) to “0” 
before switching on the unit for the first 
time .

2)  Use the button POWER (9) to switch on the 

amplifier . The power indicator ON (5) will 
light up .

3)  Turn up the control MASTER so that the 

subsequent settings can be heard well via 
the speakers .

4)  Use the mixing controls CH 1 to CH 3 (6) to 

adjust the desired volume for each chan-
nel . Turn the controls of unused channels 
to “0” .

When a mixing control must be turned 

back very far (sound too loud or distorted) 
or turned up very far (sound too low), re- 
adjust the input sensitivity with the control 
GAIN (20) of the respective channel accor-
dingly .

5)  Use the control MASTER to adjust the vo-

lume desired for the PA system . The output 
level is indicated by the LED chain OUTPUT 
LEVEL (2) .

In case of overloads, indicated by the 

LED CLIP (3), turn back the control MAS-
TER and / or the mixing controls of individual 
channels accordingly .

CAUTION

Never adjust the amplifier to a 
very high volume . Permanent 
high volumes may damage 
your hearing! 

Your ear will get accustomed to high vol-
umes which do not seem to be that high 
after some time . Therefore, do not further 
increase a high volume after getting used 
to it .

6)  Use the controls TREBLE and BASS (7) to 

adjust the sound . Then readjust the volume, 
if required .

7)  When the LED PROT (4) lights up during 

operation (brief lighting up during switch-on 
and switch-off does not indicate an error), 
the amplifier is overheated .

When a protective circuit is activated, switch 
off the PA system and then identify and elimi-
nate the error (e . g . overload, short circuit at 
the speaker output, overheating due to insuf-
ficient cooling) .

7  Specifications

RMS output power:   .  .  .  60 W
THD:  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  <  0 .1 %
Speaker output:  .  .  .  .  .  .  100 V, 

70 V, 
4 −16 Ω

Inputs
 Sensitivity:   .  .  .  .  .  .  .  .  .  1 .5 – 320 mV
 Connection:  .  .  .  .  .  .  .  .  combined 

XLR  / 6 .3 mm  jack 
(bal .)

  Phantom power:  .  .  .  .  . 

 24 V, can be addi-

tionally activated

Frequency range:   .  .  .  .  .    80 – 16 000 Hz
Tone control
  Low frequencies:   .  .  .  .  ±12 dB / 100 Hz
  High frequencies:  .  .  .  .  ±12 dB / 10  kHz
S  /  N  ratio:  .  .  .  .  .  .  .  .  .  .  .  >  66 dB
Power supply
  Mains voltage:  .  .  .  .  .  .  230 V/ 50 Hz
  Power consumption:  .   .  120 VA
 Emergency
  power supply:  .  .  .  .  .  .  . 

 24 V/  3 A

Ambient temperature:   .  0 – 40 °C
Dimensions*:  .  .  .  .  .  .  .  .  430 × 88 × 225 mm 

(W × H × D)

Rack spaces:  .  .  .  .  .  .  .  .  .  2 RS
Weight:   .  .  .  .  .  .  .  .  .  .  .  .  4 .26 kg

* without mounting brackets and feet

Subject to technical modification .

All rights reserved by MONACOR 

®

 INTERNATIONAL 

GmbH & Co. KG. No part of this instruction manual 
may be reproduced in any form or by any means for 
any commercial use.

DIP switches

Priority 1

Priority 2

Priority 3

Switch 1 “ON”, all other switches “OFF”

CH 1

CH 2,  CH 3

Switch 2 “ON”, all other switches “OFF”

CH 2

CH 1,  CH 3

Switch 3 “ON”, all other switches “OFF”

CH 1,  CH 2

CH 3

Switch 4 “ON”, all other switches “OFF”

CH 1

CH 2

CH 3

All switches “OFF”“

CH 1,  CH 2,  CH3 —

 

Prioritisation of the input channels

Summary of Contents for PA-160

Page 1: ...ODE D EMPLOI ISTRUZIONI PER L USO GEBRUIKSAANWIJZING MANUAL DE INSTRUCCIONES INSTRUKCJA OBS UGI SIKKERHEDSOPLYSNINGER S KERHETSF RESKRIFTER TURVALLISUUDESTA ELA Mischverst rker PA Mixing Amplifier PA...

Page 2: ...Page 8 Italiano Pagina 10 Nederlands Pagina 12 Espa ol P gina 14 Polski Strona 16 Dansk Sida 18 Svenska Sidan 18 Suomi Sivulta 19 ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FO...

Page 3: ...100 V 100 V CH 1 MUTE EXT PRIO PHANTOM POWER PHANTOM POWER PHANTOM POWER MIC LINE IN CH 2 MIC LINE IN CH 3 MIC LINE IN SPEAKER OUTPUT 4 16 COM 70V 100V 24V DC INPUT 230V 50Hz FUSE CH 1 CH 2 CH 3 BASS...

Page 4: ...er t zweckentfremdet nicht rich tig angeschlossen falsch bedient oder nicht fachgerecht repariert kann keine Garantie f r das Ger t und keine Haftung f r daraus resultierende Sach oder Personensch den...

Page 5: ...st in die Netzbuchse 10 und dann in eine Steckdose 230V 50Hz stecken 6 Inbetriebnahme WARNUNG Der Verst rker darf nicht ohne die Schutzabdeckung 12 be trieben werden Gefahr eines elektrischen Schlags...

Page 6: ...than originally intended if it is not correctly connected or operated or if it is not repaired in an expert way If the unit is to be put out of oper ation definitively take it to a local recycling pla...

Page 7: ...when touching the speaker terminals To prevent switching noise always switch on the units connected before switching on the power amplifier of the PA system and switch off the power amplifier before...

Page 8: ...aucun cas de produits chimiques ou d eau Nous d clinons toute responsabilit en cas de dommages corporels ou mat riels r sul tants si l appareil est utilis dans un but autre que celui pour lequel il a...

Page 9: ...ours l amplificateur a une puissance plus faible qu en fonctionnement alimentation secteur 2 Pour terminer reliez le cordon secteur la prise 10 et une prise secteur 230V 50Hz 6 Utilisation AVERTISSEME...

Page 10: ...a regola d arte dell apparecchio non si assume nessuna responsabilit per eventuali danni consequenziali a persone o a cose e non si assume nessuna garanzia per l apparecchio Se si desidera eliminare l...

Page 11: ...zione AVVERTIMENTO L amplificatore non deve es sere usato senza la copertura protettiva 12 Pericolo di una scossa elettrica toccando i morsetti per altoparlanti Per escludere rumori di commutazione ac...

Page 12: ...zelf Verwijder het stof enkel met een droge doek Gebruik zeker geen chemicali n of water In geval van ongeoorloofd of verkeerd ge bruik verkeerde aansluiting foutieve bedie ning of van herstelling doo...

Page 13: ...ijf 2 Ten slotte verbindt u het meegeleverde netsnoer eerst met de bus 10 en plugt u de stekker ervan in een stopcontact 230V 50Hz 6 Ingebruikname WAARSCHUWING De versterker mag niet zonder de bescher...

Page 14: ...ma de corriente tire siempre del enchufe Utilice s lo un pa o suave y seco para la limpieza no utilice nunca ni agua ni pro ductos qu micos No podr reclamarse garant a o responsa bilidad alguna por cu...

Page 15: ...cte el cable de corriente entregado a la toma de corriente 10 y luego a un enchufe 230V 50Hz 6 Puesta en Marcha del Amplificador ADVERTENCIA No utilice nunca el aparato sin la tapa de protecci n 12 Co...

Page 16: ...kkiej ciereczki nie u ywa wody ani rodk w chemicznych Producent ani dostawca nie ponosz odpo wiedzialno ci za wynik e szkody uszkodze nie sprz tu lub obra enia u ytkownika je li urz dzenie by o u ywa...

Page 17: ...acza bez za o onej pokrywy 12 dotkni cie terminali 14 grozi pora eniem pr dem Aby unikn trzasku w g o nikach przed w czeniem wzmacniacza nale y w czy wszyst kie pozosta e urz dzenia natomiast wy cza w...

Page 18: ...kommersiellt syfte L s nedenst ende sikkerhedsoplysninger op m rksomt igennem f r ibrugtagning af en heden Bortset fra sikkerhedsoplysningerne henvises til den engelske tekst Sikkerhedsoplysninger De...

Page 19: ...to pistorasiasta l k k ynnist laitetta jos 1 laitteessa tai virtajohdossa on havaittava vaurio 2 putoaminen tai muu vastaava vahinko on saattanut aiheuttaa vaurion 3 laitteessa esiintyy toimintah iri...

Page 20: ......

Page 21: ......

Page 22: ...MONACOR INTERNATIONAL GmbH Co KG Zum Falsch 36 28307 Bremen Germany Copyright by MONACOR INTERNATIONAL All rights reserved A 1818 99 01 01 2017...

Reviews: