27
3. SYSTEM SETTING CHECK & VOLUME CHECK
Code
04h
2
R
unsigned 16
30009
System Setting Check
Bytes
Data Mag.
R/W
Unit
Address
Parameter
Channel 1
Data HI AMP Check Interval Time
0 ~ 6 Time Step
0 = 0.5 Hour
1 = 1 Hour
2 = 1.5 Hour
3 = 3 Hour
4 = 6 Hour
5 = 12 Hour
6 = 24 Hour
Data LOW
bit 7~ bit 4 Reserved
bit 3 Sleep Mode
(0=OFF, 1= ON)
bit 2 AMP Check
(0=OFF, 1= ON)
bit 1 HPF
(0=OFF, 1= ON)
bit 0 Battery
(0=NON, 1= YES)
Data Type
30010
Channel 2
Channel 3
Channel 4
30011
30012
4. VU METER & FAULT STATUS CHECK
Code
04h
2
R
unsigned 16
300013
Fault Monitoring
Bytes
Data Mag.
R/W
Unit
Address
Parameter
Channel 1
Data HI
0 ~ 99, 100 VU METER
(0~99= Normal, 100= Clipping)
Data LOW
bit 7 Reserved
bit 6 AMP Check Error
bit 5 Over Load. Mute
bit 4 Over Temp. Mute
bit 3 Over Temp. Limit
bit 2 Battery Low Volt.
bit 1 AC Low Volt
bit 0 Over current
(0= Normal, 1=Fault)
Data Type
30014
Channel 2
Channel 3
Channel 4
30015
30016
5. SYSTEM PRESET
Code
10h
2
W
unsigned 16
40000
System Preset
Bytes
Data Mag.
R/W
Unit
Address
Parameter
Data HI
bit 15 ~ bit 8 Reserved
Data LOW (Power ON / OFF Control)
bit 7 ~ bit 1 Reserved
bit 0 Power ON / OFF
(0=OFF, 1=ON)
Data Type