Starting Generator
The generator is controlled by either a remote switch on dash, or switch located on
generator. To start generator, shut off all 120V AC appliances/equipment. Push start
switch and hold until generator is running and release switch. Dash switch will be lit
when generator is running. Normally the generator will start running within 5 seconds;
if it fails to start after cranking for 10 seconds, release switch and wait 30 seconds before
cranking again. If the generator fails to start after 5 attempts, allow starter motor to cool
down for 5 minutes before cranking again.
Stopping Generator
Turn off all 120V AC appliances/equipment and run generator for at least 3 min-
utes before turning generator off. This lets lubricating oil carry heat away from com-
bustion chamber and bearings. To stop generator, push switch to stop position for
approximately one second then release. For in-depth information regarding low oil shut-
down protection, circuit breaker locations and maintenance procedures, refer to manu-
Monarch
6-5
M
ONACO
2000
Electrical Systems
Electrical Systems
!
WARNING
!
Do not block service compartment ventilating air inlets and outlets. Engine
requires a constant supply of cooling air. Do not operate generator when
motorhome is parked in high grass or brush. Engine exhaust could ignite grass or
brush and resulting fire could cause property damage, and/or personal injury or
death.
When motorhome is in parked position, move the dash air conditioner con-
trol in OFF position to prevent outside air from entering motorhome.
Engine exhaust gases contain carbon monoxide which is an odorless and col-
orless gas. Carbon monoxide gas is poisonous and can cause unconsciousness
and/or death. Inspect exhaust system thoroughly before starting engine. Do not
block exhaust pipe or situate motorhome in a place where exhaust gases have any
possibility of accumulating either outside, underneath, or inside motorhome or any
nearby vehicles. Operate generator only when safe dispersion of exhaust gases can
be assured and monitor outside conditions to be sure that exhaust gases continue
to be dispersed safely.
When working in generator compartment, remove house battery ground
cable and turn HOUSE BATTERY disconnect to OFF position to avoid personal
injury.
Failure to turn off 120V AC appliances/equipment when starting and/or
stopping generator may damage transfer switch and/or electrical problems.
Summary of Contents for Monarch 2000
Page 66: ...NOTES Monarch 4 10 W Water Systems ater Systems MONACO 2000...
Page 92: ...NOTES Monarch 7 10 Unit Care Maintenance Unit Care Maintenance 2000 MONACO...
Page 106: ...NOTES Monarch Diagrams S Diagrams Specifications pecifications 2000 8 14 MONACO...
Page 122: ...NOTES Monarch 9 16 Chassis Information Chassis Information MONACO 2000...
Page 123: ...Monarch 9 17 MONACO 2000 Chassis Information Chassis Information...