HarshIO 300 ePN
53
IP67 Digital I/O Modules for PROFINET IO
8.
Annex
PROFINET IO Record
Below is the list of PROFINET Records supported by the module.
PROFINET
Index
Description
Information
0x8000
ExpectedIdentificationData
This returns the current expected configuration
for the specified connection
0x8001
RealIdentificationData
This returns the current expected configuration
for the current Device
0xF020
ARData for one API
This returns the entire Connection data (AR) for a
specified API
0xF820
ARData
This returns the entire Connection data (AR) for
this device
0x8000
ExpectedIdentificationData for one
Subslot
This returns the Expected identification (Slot,
Subslot, SlotID SubslotId...) for one subslot.
0x8001
RealIdentificationData for one Subslot
This returns the real identification (Slot, Subslot,
SlotID SubslotId…) for one subslot.
0xC000
ExpectedIdentificationData for one
slot
This returns the Expected identification (Slot,
Subslot, SlotID SubslotId…) for one slot.
0xC001
RealIdentificationData for one slot
This returns the real identification (Slot, Subslot,
SlotID SubslotId…) for one slot.
0xE000
ExpectedIdentificationData for one AR
This returns the Expected identification (Slot,
Subslot, SlotID SubslotId..) for one AR.
0xE001
RealIdentificationData for one AR
This returns the real identification (Slot, Subslot,
SlotID SubslotId…) for one AR.
0xE002
ModuleDiffModule for one AR
This returns the module diff module (difference
between Real configuration and expected
identification) for one AR.
0xF000
RealIdentificationData for one API
This returns the real identification (Slot, Subslot,
SlotID SubslotId…) for one API.
0xF840
I&M0FilterData
This returns the I&M0 Filter Data
0x8028
RecordInputDataObjectElement for
one Subslot
This returns the Input data object for one Subslot
0x8029
RecordOutputDataObjectElement for
one Subslot
This returns the Output data object for one
Subslot
0xF821
APIData
This returns the API data for this device
0xF830
LogData
This returns a log of each error return by
IO-Device on network. Moreover it returns also
the status for each positive or negative record
(read or write) in this PROFINET IO-Device. The
logger is limited to 10 events.
Summary of Contents for Brad HarshIO 300 ePN
Page 5: ...HarshIO 300 ePN v IP67 Digital I O Modules for PROFINET IO ...
Page 14: ...HarshIO 300 ePN 14 IP67 Digital I O Modules for PROFINET IO ...
Page 23: ...HarshIO 300 ePN 23 IP67 Digital I O Modules for PROFINET IO ...
Page 54: ...HarshIO 300 ePN 54 IP67 Digital I O Modules for PROFINET IO ...
Page 55: ...HarshIO 300 ePN 55 IP67 Digital I O Modules for PROFINET IO ...