RHT5758-CC Hand Crimp Tool  

Doc No.  64001-1000 

Release Date: 12-11-02

 

UNCONTROLLED COPY

 

Page 4 of 6 

Revision: B 

Revision Date: 09-02-03 

 

 

Tool Calibration 

 
A Certificate of Calibration (see last page) was supplied with the tool.  To 

recalibrate this tool, pin gauge measurements should be taken in each 
conductor nest and compared to this chart.  The tool should be lubricated 
prior to recalibration to ensure consistent measurements. Handle preload is 
factory set to 25-45 LBS. See How to Adjust Tool Preload (See Figure 5) to 
recalibrate. 
 
 
 

 

 

 

 

 

 

 

 

 

Warranty 

 
This tool is for electrical terminal crimping purposes only.  This tool is made of the best quality materials. All vital components are long-
life tested.  All tools are warranted to be free of manufacturing defects for a period of 30 days.   Should such a defect occur, we will 
repair or exchange the tool free of charge.  This repair or exchange will not be applicable to altered, misused or damaged tools.  This 
tool is designed for hand use only. Any clamping, fixturing, or use of handle extensions voids this warranty.  

 
Hand held crimping tools are intended for low volume, prototyping or repair requirements only. 

 

 

 
 
 
 

 
 
 
 
 

 
 
 
 
 

Wire Range 

“X” Dimension 

Conductor Crimp 

Nest 

Color 

Code 

AWG 

mm² 

Mean 

 

Go 

 No Go 

Crimp 

Inspection 

Marking 

Blue 

14 - 16 

1.30 - 2.00 

.094 

.091 

.098 

PIN GAUGE IN 

CONDUCTOR CRIMP 

“ Confining ” Crimp 

Caution:

 Repetitive use of this tool should be avoided

Summary of Contents for 64001-1000

Page 1: ... is shown in pounds and indicates the minimum acceptable force to break or separate the terminal from the conductor UL 310 Quick Disconnects The following is a partial list of the product part numbers and their specifications that this tool is designed to run We will be adding to this list and an up to date copy is available on www molex com Wire Size 14 16 AWG 2 00 1 30 mm Wire Strip Length Insul...

Page 2: ... top of the locator and the other is stored on the bottom of the locator 2 Push the terminal onto the tab locator all the way to the stop in the color coded nest The barrel of the terminal should be up See Figure 1 3 Partially close the tool to hold the terminal in place See Figure 2 4 Insert the properly stripped wire into the terminal barrel See Figure 2 and 3 Cycle the tool 5 Remove the crimp a...

Page 3: ...bjects from becoming lodged in the crimping dies and store the tool in a clean dry area Miscrimps or Jams Should this tool ever become stuck or jammed in a partially closed position Do Not force the handles open or closed The tool will open easily by pressing the ratchet release lever See Figure 5 How To Adjust Tool Preload See Figure 5 Over the life of the tool it may be necessary to adjust tool ...

Page 4: ...es only This tool is made of the best quality materials All vital components are long life tested All tools are warranted to be free of manufacturing defects for a period of 30 days Should such a defect occur we will repair or exchange the tool free of charge This repair or exchange will not be applicable to altered misused or damaged tools This tool is designed for hand use only Any clamping fixt...

Page 5: ...E Rings 1 2 63810 0000 Handle 1 3 64001 0275 Locator Assembly 1 4 64001 1070 Tooling Kit 1 Tooling Kit Only 5 64001 1001 Conductor Punch 1 6 64001 1002 Conductor Anvil 1 7 64001 1012 Insert Punch 1 8 64001 1011 Insert Anvil 1 9 N A 4 mm Dia by 5 0 mm Lg Roll Pins 2 Figure 6 M4 X 30LG PAN HEAD SCREW FOR SPRING ACCESS SWING OPEN COVER 6 SCREW AND PLASTIC COVER FOR HANDTOOL PRELOAD ADJUSTMENT RATCHET...

Page 6: ...he Tips ______________ Actual _____________ Pin Gauge of Conductor Nest Nests or Slug height if the nest is the F Crimp style Range Conductor Nest 1 ____________ Actual ______________ Range Conductor Nest 2 ____________ Actual ______________ Range Conductor Nest 3 ____________ Actual ______________ Technician ______________ Date of Calibration ______________ Calibration should be done every 5 000 ...

Reviews: