5.10.2 Step Installation
WARNING
Step may be heated. Use appropriate PPE during this procedure.
1. After the nozzle is installed, mount the step on top of the nozzle.
2. Apply anti-seize compound to the thread of each screw.
3. Lower the manifold into position on top of the step.
4. Install the screws through the manifold and the step into the nozzle.
5.
Torque screws to the value specified on the General assembly drawing.
Manifold
Screw
Step
Nozzle
Figure 5-6 Step installation
5-13
ASSEMBLY
Hot Runner User Manual
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.