18.9 Melt-Disk System Shutdown
CAUTION
Ensure that the correct shutdown procedure for your system is used.
For systems with a standard Melt Link, see
:
“18.8.1 Startup - Melt Link” on page 18-11”18.9.1 Shutdown - Melt Link” on
For systems with a Reverse Melt Link, see
:
“18.9.2 Shutdown - Reverse Melt Link ONLY” on page 18-14.
Failure to follow the correct procedure could result in damage occurring in
the Hot Runner.
CAUTION
See also “Section 8 - System Startup and Shutdown” and your controller user
manual.
18.9.1 Shutdown - Melt Link
CAUTION
Failure to follow this procedure may result in leakage or damage occurring
in the Hot Runner.
CAUTION
IMPORTANT
Thermally sensitive materials should be purged from the Hot Runner
system prior to shutdown using a thermally stable material with a similar
processing temperature.
Maximize decompression stroke prior to shutdown.
This will minimize drool at startup when there is limited gate cooling.
1. Reduce nozzle temperatures to 150°C (300°F).
2. Reduce Melt-Disk temperatures to 150°C (300°F).
3.
Turn off all zones.
18-13
MELT-DISK SYSTEM
Hot Runner User Manual
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.