5.8.2 Install Heater Plates
CAUTION
This is a pinch point area. Use caution when installing the heater plate to
the manifold plate. Failure to do so could result in damage to the
thermocouple.
Do not overtighten the mounting screws. This could result in the heater
plate losing contact with the manifold plate.
Refer to the General Assembly drawing for the correct torque values.
It is recommended that the heater plate wires be isolated and grouped
so that they do not have to be disconnected if the manifold needs to be
dismantled for repair.
CAUTION
1. Install the heater plate to the manifold. Refer to the General Assembly
drawing for location. Use anti-seize compound on threads. Bolt and
torque screws in a crossing pattern, gradually increasing torque to
specified value. Refer to the General Assembly drawing for torque values.
2. The heater plates are supplied with the power wires connected. Place a
zone number on each wire and thermocouple.