9-3
SYSTEM INSTALLATION
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
Dura+ User Manual
4. Install the anti-rotation dowel into the mold.
Bridge
Mold plate
Anti-rotation
dowel
Gap
9.2.4 Install Bridge Assembly
CAUTION
Match drop numbers stamped on bridge during assembly.
CAUTION
NOTE
Bridge mounting screws should be torqued 1/3 higher than specified on the
General Assembly drawing.
1.
Measure and confirm locator height as specified on General Assembly
drawing.
2. Align bridge to sub-manifold and locate on manifold locator.
3. Take care not to pinch the wires.
4. Remove any installation tools used.
5. Apply anti-seize compound to the bridge screws.
6. Torque bridge screws in a crossing pattern gradually increasing torque to
specified value. Refer to the General Assembly drawing for torque values.
7.
Measure and confirm drop height as specified on General Assembly
drawing.
8. Repeat for each drop.
Install Manifold Locator and Anti-Rotation Dowel -