5-2
Dura+ User Manual
ASSEMBLY
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
5.2 Pre-Assembly Checks of Gate Seals and
Nozzle
CAUTION
Gate seals are torqued at ambient (room) temperature at
Mold-Masters
. Please torque each seal at processing temperature to the
torque value specified to prevent material leakage from the gate seal.
CAUTION
1. Apply die spotting blue compound to the gate seal (and liner, if used) to
ensure a proper contact on sealing surface.
2.
Torque the gate seal to specified value. Refer to the General Assembly
drawing for torque values.
3. Remove the gate seal and verify transfer of die spotting blue compound
from gate to the liner and to nozzle. If not 100% blue on the face, contact
your
Mold-Masters
representative.
4. Clean die spotting blue compound from components.