11-13
MAINTENANCE PROCEDURES
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
Dura+ User Manual
11.11.2 System and Plate Screw Torques
CAUTION
Bridge manifold mounting screws should be torqued 1/3 higher than
specified on General Assembly drawings.
CAUTION
Quality and length of screws must be as specified on
Mold-Masters
General
Assembly drawings.
Table 11-3 Torque Chart for System Assembly Screws
Metric
Torque Setting
Imperial
Torque Setting
M5
7 Nm
#10-32
5 ft lbs
M6
14 Nm
1/4-20
10 ft lbs
M8
20 Nm
5/16-18
15 ft lbs
M10
40 Nm
3/8-16
30 ft lbs
M12
60 Nm
1/2-13
45 ft lbs
M16
145 Nm
5/8-11
107 ft lbs
M20
285 Nm
3/4-10
210 ft lbs
Table 11-4 Torque Chart for Plate Assembly Screws
Metric
Torque Setting
Imperial
Torque Setting
M5
9 Nm / 6 ft lbs
#10-32
7 Nm / 5 ft lbs
M6
15 Nm / 11 ft lbs
1/4-20
16 Nm / 12 ft lbs
M8
36 Nm / 27 ft lbs
5/16-18
33 Nm / 24 ft lbs
M10
72 Nm / 53 ft lbs
3/8-16
59 Nm / 44 ft lbs
M12
125 Nm / 92 ft lbs
1/2-13
144 Nm / 106 ft lbs
M16
311 Nm / 229 ft lbs
5/8-11
287 Nm / 212 ft lbs
M20
606 Nm / 447 ft lbs
3/4-10
511 Nm / 377 ft lbs
NOTE
Torque sequence and step torquing:
It is recommended that system screws be torqued in a standard bolt
pattern and that the specified torque is achieved in 3 steps (1/3, 2/3 and full
torque).