MV-A00000920
MOHAWK V-A SERIES: VERTICAL RISE DRIVE-ON MANUAL
35,000 - 64,000 LB MODEL
4-4
4.3.
Place of installation
The free space around the table must satisfy applicable regulations and
be no less than 700 mm or 27,5 inches.
The control unit must be positioned so that the operator has a full
view over the lift area.
To install the anchor capsules, the foundation must have the following
characteristics:
FOUNDATION
Tamped
THICKNESS OF CONCRETE
20 cm / 8 inches
CONCRETE RESISTANCE CLASS
C 25 / 4000 psi
IMPROVED ADHERENCE STEEL GIRDERS Type FeB 44 K
REINFORCEMENT GIRDERS FOR LARGE
SURFACES
Electro welded mesh
REINFORCEMENT GIRDERS FOR SMALL
SURFACES
Bent irons
FLATNESS
1 / 1000
If the floor characteristics are not available, foundations must be
provided underneath the lift's clamping holes.
“Ensure a qualified person should be consulted to address seismic loads
and other local or state requirements”.
MAX.GROUND PRESSURE (*)
Kg/cm
2
5
psi
70
The lift must in any case be fastened to the floor using
dedicated chemical anchor capsules.
(*)
press calculated under the base plates.
WORK AT A ROOM
TEMPERATURE OF
-10 TO 40 ° C.
14 TO 104 °F
Summary of Contents for V-035-A-X
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 14: ......
Page 22: ...MV A00000920 MOHAWK V A SERIES VERTICAL RISE DRIVE ON MANUAL 35 000 64 000 LB MODEL 3 8 LIFT ...
Page 28: ......
Page 38: ...MV A00000920 MOHAWK V A SERIES VERTICAL RISE DRIVE ON MANUAL 35 000 64 000 LB MODEL 4 10 ...
Page 60: ......
Page 61: ...MV A00000920 MOHAWK V A SERIES VERTICAL RISE DRIVE ON MANUAL 35 000 64 000 LB MODEL 7 1 ...