MV-A00000920
MOHAWK V-A SERIES: VERTICAL RISE DRIVE-ON MANUAL
35,000 - 64,000 LB MODEL
4-15
4.10.
Anchorage capsule installation
1. Drilling the hole;
2. Clean the inside of the hole;
3. Push the anchor capsule into the drilled hole;
4. Driving the anchor rod into the hole;
5. Waiting for the solidification time (t
rel
)
6. Waiting for the hardening of the compound (t
cure
);
7. Close with the prescribed tightening torque(T
inst
).
ANCHORAGE CAPSULE POSITION
BASE
A = OBLIGATORY ANCHORAGE CAPSULE
B = OPTIONAL ANCHORAGE CAPSULE
(according to the foundation characteristics and dimension)
TYPE OF ANCHOR CAPSULE
HVU M16X125
TYPE OF ANCHOR ROD
HAS M16X190
DRILL BIT DIAMETER
d0
mm/inches
18/0.75
MIN. BORE DEPTH
h1
mm/inches
125/5
MIN. THICKNESS OF
CONCRETE
h
mm/inches
170/7
LIFT BASE SPACER
mm/inches
38/1.5
HOLE DIAMETER
mm/inches
18/1
TIGHTENING TORQUE
T
inst
Nm/ft lbf
100/74
DRILL BIT
TE-T
18-32
NUMBER OF PINS
N°
16 or more