Wiring with easy
108
05/04 AWB2528-1508GB
Parameter display in RUN mode
Parameter display and parameter set for analog value
comparator in RUN mode with the display of the actual
values:
Resolution of the analog inputs
The analog inputs I7, I8, and on the easy700 I11, I12 have
the following resolution.
The analog signal from 0 to 10 V DC is converted to a 10-bit
digital value from 0 to 1023. A digital value of 100
represents an analog value of 1.0 V (exactly 0.98 V).
h
If the value of a control relay exceeds the value 9999, the
value of the counter is shown in the display of the analog
value comparator minus 10000.
Example: Counter actual value =10233
Display of the analog value comparator: 233 (10000 is
displayed as 0).
Actual value, e.g.: analog input
Factor is not used
Actual comparison value, e.g.: constant
Factor is not used
Offset is not used
The switching hysteresis is +/– 25
A1 EQ
+
I1 0249 Æ
F1 0000
I2
0350 æ
F2 0000
OS 0000
HY 0025