Functions of different sensors
How can I connect external sensors?
You can also connect external sensors to Compact IIP+A. The connected sensor must operate with standards NO or NC. You can
connect as well simple short/open detectors. The defined mode allows you to choice type of the external equipment between
normally opened and normally closed. There is a time as well to redirect application to give alarm when the sensor is active for
longer than programmed time. The time field must be left blank when you want to have immediately alarm for any sensor
activity. Please find more information below.
SET
NO
(space)
(space)
156
Extern sensors activated.
Operational mode of the sensor,
loop attached: NO or NC
Request time for closing (NO) or opening (NC)
of the external circuit for the alarm.
This command will program MC to give alarm
when the external contact will be closed for
longer than 156 seconds (f. ex.)
The command SET EXTERN NC will program
MC to give alarm when the external contact
will be opened for short period of time
(500 ms typical)
From 1 up to 360 seconds!
EXTERN
(space)
max. 2 meters
stereo plug, 2.5mm
2-wire cable
SET
PIR
(space)
(space)
MID
EXTERN
(space)
This command will provide service of external motion sensor (PIR). In this mode external connector is SET only for PIR.
Sensitivity of PIR sensor can be adjusted at three levels (low/mid/high).
Note:
Please use only original Compact IIP+A motion sensor.