30
Compact IIP+A as an alarm system
How will I be informed in case of an alarm? 1/2
You can choose by yourself in which kind you and the other people (saved numbers under the three keys) have
to be informed in alarm situations.
For the numbers you have saved with the commands SET KEY/2/3, you can choose the way of information as
below, for the further three SMS-numbers you have saved (see page 24) please consider the steps on next page.
SET
ALARM
(space)
(space)
Now, the way of the alarm
information is saved.
C0S
C
means calling
the accordingly number in alarm
situation for max
3 minutes
.
S
means sending an SMS
to the accordingly number
in alarm situation.
0
means that
the accordingly number wont
be informed in alarm situation.
C = letter
S = letter
0 = zero (not a letter)!
You can choose any individual row of the letters resp. digits. First letter is the way of information for number 1
(red key), the second letter is for the number 2 (green key) and the third letter is for the number 3 (blue key).
SMS with low battery alarm and status alarm will be send only to numbers assigned as „