9
2.6 CONNECT AN EXTERNAL POWER SUPPLY (OPTIONALLY)
Although the Mobeye CML2255 is designed to run on batteries, it is possible to use an
external power supply. In this mode the module is always connected with the GSM
network and therefore always in program mode. When the power fails, the batteries
take over and a power failure alarm message is sent. The module continues operating
albeit in the low power mode. This means the GSM module switches off and only
establishes network connection when it needs to send an alarm notification, test
message or low battery alert.
Connect the external power adapter (or any other
regulated 12VDC power supply) to the power input
of the connector (press on the green pins to
connect the wires):
-
V+ (black lead with white stripe) to “+”
-
Ground (black lead) to “-“
2.7 ENTER THE PROGRAM MODE
To activate the device in the portal, the unit needs to be in program mode, i.e. the GSM
module is open and connected to the network. Using external power, the unit is always
in program mode.
Directly after inserting the batteries, the Mobeye CML2255 switches to the program
mode. First the GSM module establishes network connection. During this time the LED
flashes green and red. Within 10-30 seconds the connection is established and the
status LED starts flashing 1 sec. on/1 sec. off (or stays on continuously in case the first
telephone number has been configured).
The Mobeye CML2255 returns to the program mode by pressing the on/off button for 5
seconds, until the LED starts flashing red/green. Once it has GSM connection it will be
flashing again (or stays on continuously).
As long as the unit is in program mode, the status green LED is on (or flashing 1 sec.
on/1 sec. off if the module has no configuration). During the first 3 minutes, the GSM
module remains active, ready to be activated in the portal. After 3 minutes a time-out