SMS-command temperature calibration:
TOFFSET:
example: 1111 TOFFSET:0,5
5.16 AUTOMATIC ARMING / DISARMING
The Mobeye ThermoGuard only works if the unit is armed, which is done via the on/off
button. It is possible to automatically arm and disarm the unit, based on an arming
and/or disarming time scheme. Two schemes can be entered, which can be assigned to
the days in the week (e.g. to have a different weekend scheme).
For arming/disarming automatically, the internal clock time needs to be correct. Some
telecom providers offer this in the network, which the Mobeye ThermoGuard
synchronizes during start-up and after sending test messages. It is possible to set the
time manually. To view the clock time, request a list of the settings by sending the
command 1111 SET?.
To set the actual date:
SMS command actual date:
DATE:
To set the actual time:
SMS command actual time:
TIME:
To set a daily arming scheme:
SMS command arming scheme 1:
TIMEARM1:
To set a daily disarming scheme:
SMS command disarming scheme 1:
TIMEDISARM1:
To set a second daily arming scheme:
SMS command arming scheme 2:
TIMEARM2:
To set a second daily disarming scheme:
SMS command disarming scheme 2:
TIMEDISARM2:
example: 1111 TIMEDISARM2:1455