© MOBATIME
12 / 32
801151.06
3.5 Slave clock controlled by supervised RS485
Supervised RS485 line available on the DTS.480x timeservers offers exact time
synchronization as well as monitoring the correct function of connected slave clocks.
•
If the ECO-M-DC clock should be monitored set in menu item
P5
unique address
in the range 1 to 32. The value "L" means that the clocks are synchronized only
(without monitoring).
•
It is necessary to register the clock under the used address in DTS.
•
The time synchronization starts within a few tens of seconds after start-up.
•
Failure of slave clock function is signalized by an alarm in DTS.