2.3 Double-sided clock
•
First, prepare the 4 holes in the ceiling or wall by bracket flange pitch.
•
Insert the dowels to the prepared holes and fix into them the ceiling or wall bracket using
appropriate screws.
•
Remove the screws on the bottom of the Master clock. Remove the bottom cover and
plexiglass (see picture in capture 2.1 Single-sided clock).
•
Except PoE variant use the power cable of at least 3 x 0.5 mm
2
(double insulation),
maximum of 3 x 1.5 mm
2
(double insulation).
•
Cut the cable(s) to the appropriate length and connect the wires to corresponding
terminals and/or crimp the RJ45 jack to the Ethernet cable respectively.
•
Insert the BATT jumper in order to ena
ble the RTC backup (doesn’t apply to clocks with
supercapacitor option).
•
Connect the cable from Slave clock to the Master clock.
•
Mount the plexiglass and bottom cover.
2.4 Assembly diagram