background image

© MOBATIME

 

5 / 32 

801151.06 

 

Description 

The  ECO-M-DC 

series  •  elegant  and  very  slim  digital  clocks  for  displaying  time  and  date  • 

aluminum  metal  housing,  powder  coated  •  high  protection  degree  IP54  as  standard  for  all 
versions  •  7

-segment  LED  display  of  high  luminance  provide  for  excellent  readability  from 

various  angles  of  view  •  features  six  combinations  of  the  height  and  the  number  of  digits  • 
autonomous  operation  with  internal  quartz  powered  from  mains  •  NTP  multicast    or  unicast 

synchronization powered over PoE (compatible IEEE 802.3af)  or mains powere

d • slave clock 

operation controlled by MOBALine,  DCF 77, GPS, RS485 or by IRIG-

B, mains powered • LED 

display in red, green, yellow, blue or white colour • single or double sided clock • wall mounting 

for single-

sided clock • ceiling suspension or wall b

racket mounting for double-sided clock  

 

 

 

Display features 

   time display in four digits (HH:MM) or six digits (HH:MMSS HH:MM

SS

) either 12 or 24 hours 

format  

   date display in four digits (DD.MM.) or six digits (DD.MM.YY, DD.MM

YY

   7 segment LED displays with either 57, 75 or 100 mm digit height for a viewing distance up 

to 25, 32 or 40 m  

  alternating display of time and date  

   display available in the red, green, yellow, pure green, blue or white colour  

   automatic or manual adjustment of the display brightness 

   powered from mains with wide input voltage range 100-240VAC,                                  

optionally from 24 VDC voltage or through PoE (IEEE 802.3af) 

   redundant power option on request 

 

Mechanic 

  elegant and slim clock frame, made of aluminium, powder coated in black or silver colour  

  front cover made of dark plexiglass for best readability over a wide viewing angle  

  single- or double-sided version for wall mounting, ceiling suspension                                        

or wall bracket mounting  

  double sided version consist of two pieces single sided clock and wall bracket                    

or ceiling suspension  

  easy two-step installation and time-saving maintenance, hanging holes for wall mounting 

  push butons, connectors and state LEDs are accessible after dismounting                             

the front plexiglass  

  protection degree IP54 

  working temperature  - 

5 to +55°C 

 

 

Synchronization 

  automounos operation with internal quartz time base with programmable automatic              

seasonal time change  

   NTP multicast or unicast synchronization powered over PoE or mains powered  

  slave clock operation with synchronization by MOBALine, Active DCF 77, RS485                          

or by IRIG-B (depending on version), mains powered 

  accuracy 

±

0.1 s / day without synchronization (after 24 hours of synchronization  

at constant temperature) 
RTC backup by means of lithium battery CR2032 (supercapacitor on request) 

 

Summary of Contents for DC.100.4

Page 1: ...MOBATIME 801151 06 USER MANUAL Economy LED digital clock ECO M DC series...

Page 2: ...tmost care in order to explain all details in respect of the operation of the product Should you nevertheless have questions or discover errors in this manual please contact us 3 We do not answer for...

Page 3: ...17 5 2 Calculation using MOBALine time zones 17 5 3 Calculation using Time zone server MOBATIME 17 5 4 Calculation using time zone entries preconfigured by MOBA NMS software 17 5 5 Calculation accordi...

Page 4: ...MOBATIME 4 32 801151 06 11 2 Double sided clock 30 11 3 Cleaning 30...

Page 5: ...in the red green yellow pure green blue or white colour automatic or manual adjustment of the display brightness powered from mains with wide input voltage range 100 240VAC optionally from 24 VDC volt...

Page 6: ...on only DHCPv4 DHCPv6 manual configuration of the clock parameters or setting over the telnet private options of DHCPv4 and DHCPv6 string for automatic configuration of all clock parameters when conne...

Page 7: ...110 230 V AC power network should be carried out when the mains power is off 2 1 Single sided clock First prepare the 2 holes in the wall by hinges pitch on the backside of clock Insert the dowels to...

Page 8: ...e in capture 2 1 Single sided clock Except PoE variant use the power cable of at least 3 x 0 5 mm2 double insulation maximum of 3 x 1 5 mm2 double insulation Cut the cable s to the appropriate length...

Page 9: ...DC 57 4 ECO M DC 57 6 ECO M DC 57x 6 ECO M DC 75 4 ECO M DC 75 6 ECO M DC 75x 6 ECO M DC 100 4 ECO M DC 100 6 ECO M DC 100x 6 Dimension A 325 405 435 395 490 540 520 610 725 B 126 126 126 143 143 143...

Page 10: ...5 LAN version NTP PoE PoEclass 100 240 VAC except PoE PoEclass DISP2 PROG Setting elements PB1 PB2 buttons control buttons RESET reset button jumper BATT backup battery connection jumper ISPE inductio...

Page 11: ...formation The synchronization takes 6 15 seconds for MOBALine or 3 5 minutes for Active DCF 77 For MOBALine it is possible to use the time zone function the zone is selected by menu item P5 The colon...

Page 12: ...of connected slave clocks If the ECO M DC clock should be monitored set in menu item P5 unique address in the range 1 to 32 The value L means that the clocks are synchronized only without monitoring...

Page 13: ...m the NTP server If the server is not available the clock tries to contact the other defined servers in cyclic way until the valid response from the NTP server is received This operating mode supports...

Page 14: ...Manual setting through setup menu The menu item P8 must be set to value 2 See chapter 7 2 2 for setting the clock s IPv4 address in the item P9 submenu See chapter 7 2 3 for setting the subnet mask i...

Page 15: ...DNS domain 25 Identity Association for Prefix Delegation 31 SNTP servers The network administrator must set the DHCPv6 options on the server accordingly Assigned parameters can be checked in the P14su...

Page 16: ...ision and configuration with MOBA NMS the multicast group address can be used or the multicast group address having last octet cleared to zero The Multicast operating mode signifies only a minimum amo...

Page 17: ...l daylight saving time This setting is suitable for digital clocks controlled by a master clock as MOBALine slave clocks in a time distribution system with the possibility to display different MOBALin...

Page 18: ...sen time zone incl daylight saving time This setting is suitable for autonomous digital clocks or in cases when the displayed time is needed from another time zone than provided by the synchronization...

Page 19: ...ne see chap 5 5 U1 U7 preconfigured time zone entry by MOBA NMS P7 IP mode 0 IPv4 IPv6 1 IPv4 2 IPv6 P8 Network operation mode IPv4 1 multicast without IP address 2 unicast network param defined manua...

Page 20: ...on SLAAC e g 2001 0db8 0000 0012 f68e 38ff fee8 4a13 dHCP First address received from DHCPv6 e g 2001 0db8 0000 0012 0000 0000 0000 1000 MANU Manually set address e g fec0 1234 0000 0000 f68e 38ff fee...

Page 21: ...tes and by pushing the PB1S the entered values are stored the seconds are set to zero and the clock returns back to Clock mode Note When the time zone for local time and date calculation menu item P6...

Page 22: ...g By pushing PB2S the adjusted digit value is increased in steps of 1 by pushing the PB2L button the value will be continuously increased The display shows the following Enter the four octets of the I...

Page 23: ...PB2L to return to P12 without storage of the data 7 2 6 Submenu for setting of the NTP unicast synchronization Choose the menu item P13 then enter the submenu by pushing the PB1L pushbutton for settin...

Page 24: ...isplay 2001 0db8 0000 0012 f68e 38ff fee8 4a13 2001 first part of IPv6 address 000b 0db8 second part of IPv6 address 001b 000 0 third part IPv6 address 010b 001 2 fourth part of the IPv6 address 011b...

Page 25: ...0 the request for the telnet password will appear after entering the valid password the information about the software and hardware version followed by the MAC address appears enter the command fu in...

Page 26: ...Oct 01 00 07 UTC GMT 0 No 08 Istanbul Kuwait City Minsk Moscow Saint Petersburg Volgograd 3 No 09 Praia Cape Verde 1 No 10 UTC GMT 0 No 11 Abu Dhabi Muscat Tbilisi Samara 4 No 12 Kabul 4 5 No 13 Adam...

Page 27: ...ico 6 Yes 1st Sun Apr 02 00 Last Sun Oct 02 00 48 Adak Aleutian Is 10 Yes 2nd Sun Mar 02 00 1st Sun Nov 02 00 49 UTC GMT 0 No 50 UTC GMT 0 No 51 UTC GMT 0 No 52 UTC GMT 0 No 53 UTC GMT 0 No 54 Ittoqqo...

Page 28: ...urs with supercapacitor accuracy 0 1 s day without synchronization after 24h synchronization at constant temp Accuracy of temperature measurement range 25 to 85 C 0 5 C range 50 to 125 C 2 0 C Operati...

Page 29: ...51 06 10 2 Voltage range and electric current consumption of the lines Type of slave line Voltage range Electric current consumption MOBALine 5 30 VAC 6 34 uA Active DCF 77 12 30 V 3 7 mA IRIG B 20 mV...

Page 30: ...od screws including dowels 2 pcs 11 2 Double sided clock instruction manual 1 pc wood screws including dowels for fastening the console 4 pcs interconnecting cable for second side 1 pc Allen key for f...

Page 31: ...MOBATIME 31 32 801151 06...

Page 32: ...ch www mobatime ch MOSER BAER SA EXPORT DIVISION 19 ch du Champ des Filles CH 1228 Plan les Ouates Tel 41 22 884 96 11 Fax 41 22 884 96 90 export mobatime com www mobatime com MOSER BAER AG Spitalstra...

Reviews: