background image

72MHz Analog Clock

Install Guide

OneVue Sync 72MHz
Publication date July 19, 2020

Summary of Contents for 120 VAC

Page 1: ...72MHz Analog Clock Install Guide OneVue Sync 72MHz Publication date July 19 2020 ...

Page 2: ... respective owners The Bluetooth word mark and logos are registered trademarks owned by the Bluetooth SIG Inc and any use of such marks by Primex Inc is under license Primex is the leading provider of solutions to automate and maintain facility compliance increase efficiencies enhance safety and reduce risk for enterprise organizations in the healthcare education manufacturing and government verti...

Page 3: ...emble and install a 16 dual sided clock 13 Install dual sided slim metal series Analog Clock 16 Dual Clock Kit contents 16 Assemble and mount dual sided clock 16 Remove Analog Clock from clock lock mount 18 Remove Analog Clock from dual mount bracket 19 Replace Analog Clock batteries 20 Analog Clock operation 21 Daily signal check time update 21 Daily hand alignment position check 21 Loss of time ...

Page 4: ...ck after installation simply remove its power source for at least 10 seconds and then reapply its power source The clock automatically searches for a signal and resets its time when it receives a signal When a clock has not received a valid signal time update for three consecutive days it displays a visual signal loss indicator an analog clock s second hand advances and pauses continuously steppin...

Page 5: ...llation location to verify it can receive a signal from a Transmitter 1 At its installation location press and IMMEDIATELY release the red button located on the backside of the clock and hang the clock in place NOTE When clocks are being installed or signal tested it s very important not to hold the button down too long or the hands will proceed to the 12 o clock position and remain there indefini...

Page 6: ... configuration The power cord is wrapped around the two posts on the back of the clock and can be unwrapped or wrapped to the desired length The power cord is to be routed through the strain relief away from the upper portion of the clock s antenna to maintain optimal reception and then exit through the slot located at the bottom of the clock The excess cord can then be wound around the two cord p...

Page 7: ...ail installation Pigtail installation requires a 120V power line in a junction box installed by a licensed electrician Leave a minimum of 6 in 15 cm of cord inside the junction box NOTE To conform to UL and National Building Code the use of the clock lock feature is required for this configuration Page 7 ...

Page 8: ...Page 8 ...

Page 9: ...ansmitter It s very important to only insert a clock s batteries at its permanent install location 1 Drill holes for the screw anchors per the clock hole spacing specifications Clock Size Hole Spacing Clock Lock Feature 9 22 86 cm 6 75 17 17 cm Yes 9 5 24 13 cm 9 22 86 cm Yes 11 5 29 21 cm 9 22 86 cm Yes 12 5 31 75 cm 9 22 86 cm Yes 13 5 34 2 cm Square model 9 5 24 13 cm Yes 13 75 34 92 cm 9 22 86...

Page 10: ...d remain there indefinitely To release the hands from an indefinite position press and release the button again The clock will automatically initiate the Self Initialization procedure and set itself The clock scans all channels looking for a Transmitter signal Once the clock finds a channel with a Transmitter signal the clock emits a series of beeps Each time a valid time signal is received the cl...

Page 11: ...e each clock in the housing with the 10 11 and 4 5 numerals over the brass posts 2 Route the clock power cords to the left right or center position For right or left routing remove the dual mount bracket cover and thread the cord through the clearance hole in the bracket Lift the power cord out of the way then slide the bracket cover back onto the dual mount bracket Step 2 Mount bracket kit to wal...

Page 12: ... assembly fully into place 4 Examine the mounting plate to ensure the bracket is fully engaged The small hole in top side of the mounting plate should be visible and fully exposed To increase the security of the clock assembly a common screw may be inserted into the hole and screwed into the wall 5 Route the power cords as desired and apply AC power The clocks set to the correct time after they re...

Page 13: ...unt bracket 1 Mounting plate 4 6 x 1 2 inch long screws Screws and anchors supplied with each clock are included in the order packaging Assemble and install a 16 dual sided clock 1 At the installation location measure and drill holes into the wall or ceiling to align with the mounting plate hole spacing measurements 2 Fasten a supplied 6 x 1 2 inch long screw to each mounting post located on the b...

Page 14: ...ough the bracket opening and complete electrical connection 4 For each clock place the clock into the bracket housing with the 10 11 and 4 5 numerals over the clock lock tab and rotate clock clockwise to lock into place The screws fastened to the clock mounting posts lock into the housing clock lock tabs Page 14 ...

Page 15: ...required to set the bracket assembly fully into place 6 Examine the mounting plate to ensure the bracket is fully engaged The small hole in top side of the mounting plate should be visible and fully exposed To increase the security of the clock assembly a common screw may be inserted into the hole and screwed into the wall Page 15 ...

Page 16: ...ermanent install location Dual Clock Kit contents 1 Mounting plate 4 Long screws 4 Wall anchors Assemble and mount dual sided clock 1 Secure the mounting plate to the wall or ceiling with the four long screws paying attention to the up arrow at the location you will be hanging the clock 2 Remove one clock from the bracket by removing two of the four factory installed screws With the dual clock fla...

Page 17: ... post in the bracket next to a clip Make sure that the raised portion of the clip next to the post is inside the bracket 6 Lower the clock down on the bracket keeping all clips inside ring Press down to seat the clock in bracket Secure with the two screws removed previously in same holes in bracket over screws holding other clock in place 7 If necessary use the four additional screws included in t...

Page 18: ...Remove Analog Clock from clock lock mount Follow the illustrated steps below to remove an analog clock that has been mounted using the clock lock feature Page 18 ...

Page 19: ...the 10 11 and 4 5 positions 2 Turn each clock counter clockwise to unlock the clock housing from the twist lock mount 3 Reassemble clocks to bracket Place clock in the housing with the 10 11 and 4 5 numerals over the brass posts Place your hands at the 10 11 and 4 5 positions and turn the clock clockwise to lock into place Page 19 ...

Page 20: ...nalog Clock is over four years with use of high quality alkaline batteries Therefore it s important that fresh superior quality batteries are used with an expiration date that exceeds five years past the current year 1 Remove its batteries 2 Stretch the battery tabs in the battery holder out slightly to apply more pressure to the battery contact 3 Insert two new alkaline batteries into the battery...

Page 21: ... valid time is received the clock hands are set to the correct time and resume moving normally Manually reset a clock s time To reset a clock s time remove its batteries for 10 seconds and reinsert the batteries The clock then will go through the initial setup procedure turn on its radio to search for a time signal update from a Transmitter Once a time signal has been received the clock AUTOMATICA...

Page 22: ...cribed below Also when a signal is received the clock will reset its time Clock signal strength indicator If a signal is received clock emits a beep once per second for one minute every time a valid packet is decoded The clock hands automatically adjust to the correct time If the clock is in a marginal signal area the clock emits a beep once every few seconds Battery operated models will work in m...

Page 23: ...n wet areas is an electrical hazard and may damage the equipment while nullifying the warranty Device is cleanable with a cloth moistened with water or a common disinfectant Be sure to test any cleaning solutions on a small area of the clock before using it on the entire device Do not use caustic cleaners or abrasives Keep away from dust dirt and moisture For healthcare facilities devices are not ...

Page 24: ...re of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Radiation Exposure Statement This device complies with FCC radiation exposure limits set forth...

Page 25: ...ubi même si le brouillage est susceptible d en compromettre le fonctionnement The device meets the exemption from the routine evaluation limits in section 2 5 of RSS 102 and compliance with RSS 102 RF exposure users can obtain Canadian information on RF exposure and compliance Le dispositif rencontre l exemption des limites courantes d évaluation de routine dans la section 2 5 de RSS 102 et la con...

Page 26: ...and tear including but not limited to product batteries and cables This warranty is VOID if this product has been altered or modified in any way including but not limited to attempted warranty repair other than by Primex or an authorized service partner Limitation of Liability The warranties and remedies contained herein are exclusive and in lieu of all other warranties express or implied or statu...

Page 27: ...x products If you have purchased Primex products or have a service agreement with a Primex Partner they are your primary contact for all Technical Support inquires Primex Technical Support Make sure you have satisfied the system requirements that are listed in your product documentation Also you should be at the computer or device on which the problem occurred in case it s necessary to replicate t...