140
GB MagFlux Manual 0812
Electromagnetic Flow Meter
GB MagFlux Manual 0808
Electromagnetic Flow Meter
Type Password
0000
Back
Select
>
Sensor Calibration Code
Converter SW Ver.
Product Data
Reset Counter Time
Internal Meas. & Cal.
Minimum Velocity
Calibrate Flow now
Calibrate Volume
Calibrate mA
Test Velocity
Freeze Coil
Read Event Log
Back on Stock
Back
Select
OK
OK
Converter SW Ver.
Product Data
Converter SW Ver.
842007
7428
Bootload version 840020
681
Back
Product ID
56136
Back
Select
>
Product type No.
0000207910
Back
Select
>
Track No.
00000
Back
Select
>
HW type No.
00000510250
Back
Select
>
OK
OK
OK
Reset Counter Time
Reset Counter 11
Systen Runtime 1632838
Since reset 426838
Runtime (days) 18
Back
Select
>
Internal Meas. & Cal.
View Vgate
Coil Current
View ADC Factor
Calibrate Vground
Calibrate Vref
View Vwater
View Raw ADC
View ADC Current
Back
Select
>
Minimum Velocity
Minimum Velocity
0.100 m/sec
Back
Select
>
View Vgate
Coil Current
View Vgate
3624
Back
Select
>
Coil Current
148
Back
Select
>
View ADC Factor
4.89011
Back
Select
>
Calibrate ADC ground
2270
Back
Select
>
View ADC Factor
Calibrate ADC Ground
View ADC Current
View Raw ADC
View ADC Current
09593127.00000
Back
Select
>
Input noise 0.18%
Raw ADC 10791
Gain 4.000
Velocity 5.21656 m/sec
Flow 0.0055786500 m
3
/sec
Back
Select
>
View Vwater
0
Back
Select
>
View/Calibrate Vref
1208
Back
Select
>
View Vwater
View/Calibrate Vref
Calibrate Flow now
View flow now
0.0019816387 m
3
/sec
Back
Select
>
Sensor Calibration Code
7V3RI0
Back
Select
>
DN
00025
Back
Select
>
OK
Calibration Volume
Reset counter
Yes
No
Back
Select
OK
Reset counter
Yes
No
Back
Select
OK
OK
View counter
1163.1950000000 m
3
Back
Select
OK
OK
Set volume
1163.1950000000 m
3
Back
Select
OK
OK
Calibrate mA
Current
Set fixed current
Calib. current
DAC zero current
DAC top current
Back
Select
OK
Test Velocity
Set velocity
00.000 m/sec
Back
Select
>
Velocity
4.039745 m/sec
Flow
7.136209 m
3
/h
Back
Select
OK
OK
Enable test
Yes
No
Back
Select
OK
OK
Freeze Coil
Freeze coil
Positive
Negative
Back
Select
OK
Freeze coil
Disable
Enable
Back
Select
OK
OK
Read Event Log
No Hour Event Extension
1 1956 0 0
2 1956 3 0
3 1956 205 0
Back
Next
OK
No Hour Event Extension
18 306 205 0
19 306 208 0
20 163 206 0
Back
OK
Back On Stock
Recover Factory Settings
Cancel
Back On Stock
Back
Select
OK
Password
Specify Main Screen
Factory Settings
Data Logger
Set Sensor Name
Display Setup
Converter Setup
Main Menu
.
.
Service Menu
Set flow direction
Follow arrow A
Follow arrow B
<A--------------------------B>
Back
Select >
Service Menu
Sensor Calibration Code
OK
Gf-3
Service Menu Overview
Summary of Contents for MagFlux
Page 6: ...6 GB MagFlux Manual 0812 Electromagnetic Flow Meter This page intentionally left blank...
Page 12: ...12 GB MagFlux Manual 0812 Electromagnetic Flow Meter This page intentionally left blank...
Page 38: ...38 GB MagFlux Manual 0812 Electromagnetic Flow Meter This page intentionally left blank...
Page 106: ...106 GB MagFlux Manual 0812 Electromagnetic Flow Meter This page intentionally left blank...
Page 144: ...144 GB MagFlux Manual 0812 Electromagnetic Flow Meter This page intentionally left blank...