IPB-5000A
10. Specifications
10-2
Model name
IPB-5000A-00-00
IPB-5000A-00-01
Monitor Setting
Range
Current Upper/Lower Limit
: 0.00 to 9.99kA (0.01kA ea.)
Voltage Upper/Lower Limit
: 0.00 to 9.99V (0.01V ea.)
Power Upper/Lower Limit
: 00.0 to 20.0kW (0.1kW ea.)
Resistance Upper/Lower Limit : 00.0 to 99.9m
Ω
(0.1m
Ω
ea.)
Counter
Set at
COUNTER
. Count-up Output is produced when the
counting arrives at Pre-set value for each mode.
(1)
TOTAL
(Total Counter Mode)
Every time the weld current is supplied, Count-up (+1
increment) is performed regardless of a judgment result.
Counter Pre-set Setting Range: 000000 to 999999
(2)
GOOD
(Good Product Counter Mode)
Every time GOOD is judged, Count-up is performed
Counter Pre-set Setting Range: 000000 to 999999
(3) WORK (Production Counter Mode)
Every time the counting arrives at the set value of Weld
Counter, WORK Count is counted- up (+1 increment).
When the monitored value is judged as No Good, Count-up
is not performed.
WELD Counter Pre-set Setting Range: 00 to 99
WORK Counter Pre-set Setting Range:
000000 to 999999
Note: The period for retaining the memory of counted numbers is
approximately 10 days since the day when a power
supply is turned off at latest.
Start Signal Stabilizing
Period
Set at
START SIG. TIME
.
Weld Sequence is started after finding the set value of 1 , 5, 10 or
20ms and the Start Signal.
Self-sustaining
Method
Set at
START SIG. HOLD
.
NO HOLD
: No self-sustaining action
WE HOLD
: Self-sustaining action works from the start of current
supply
SQ HOLD
: Self-sustaining action works from the start of SQ
Schedule Select
Method
Set at
SCHEDULE#
.
EXT. (NP)
: Selected by the use of binary data
EXT. (P)
: Selected by binary data with odd-numbered parity
PANEL
: Selected on Panel
Period for outputting
END or GOOD Signal
Set at
END SIG. TIME
.
Output for 10ms, 100ms or the period during which Start Signal
is input (Note: if it is input 10ms or less, END or GOOD Signal is
output for 10ms.).
HOLD
: Output for period during which Start Signal is input
10ms
: Output for 10ms
100ms
: Output for 100ms
Monitor Computing
Range
Set at
MONITOR MODE
.
EXCLUDE SLOPE
: Computing a monitored value excluding
Slope Period
INCLUDE SLOPE
: Computing a monitored value including
Slope Period
PARITY/WE1STOP
Input Selection
Set at
PARITY/WE1STOP
.
PARITY
: Parity Input at External Input Terminal Pin 14
WE1STOP
: WELD1 Stop Input at External Input Terminal Pin 14