IPB-5000A
10. Specifications
10-3
Model name
IPB-5000A-00-00
IPB-5000A-00-01
Starting Time of
detecting No Current
or No Voltage
Set at
NO CURR MONITOR START
.
00 to 10ms (Starts to detect No Current or Voltage after the
set period)
Pulse Monitoring
Start Time
Set at
PW MONITOR START
.
00 to 10ms (Starts the pulse monitoring after the set period)
NG Output Setting
Set at
NG OUTPUT
.
NORMALLY CLOSE
: Closed with Power Supply turned on
and open with NG generated
NORMALLY OPEN
: Closed with NG generated
READY Output Setting
Set at
READY OUTPUT
.
WELD ON
: Closed with Weld Current Supply ready
POWER ON
: Closed with
IPB-5000A
turned on
Operation
Environment
Temperature 5 to 40
℃
,
Humidity 90% or less (No condensation)
Outline (mm)
269 (H) x 172 (W) x 390 (D) (No projections included)
Mass (kg)
15
(2) Optional Items (Separately Sold)
①
Input Cables
PK-01855-
□□□
If a customer procures the cable by oneself, prepare it in accordance with the
following right-hand specifications.
Type
Branch
No.
Length
(m)
Specifications of Standard Cable
-002 2
Rated Voltage
600VAC min.
-005 5
Section
Area
8mm
2
min.
-010
10
No. of Cores
4
-015
15
Cable Dia.
25 mm max.
Standard
-020 20
Type
Branch
No.
Length
(m)
Specifications of CE Marking
Compliant Cable
-102 2
Rated
Voltage
500VAC min.
-105 5
Section
Area
10mm
2
min.
-110
10
No. of Cores
4
-115
15
Cable Dia.
25 mm max.
CE
Marking
Compliant
-120 20
Compliance
Standard
Conductor:
VDE0812/0281
Insulation: