14
-
(3)
Details of control at each operation mode (pattern)
(a)
Fuzzy operation
Deviation between the room temperature setting correction temperature and the suction air temperature is calculated in
accordance with the fuzzy rule, and used for control of the air capacity and the inverter command speed.
(b)
Heating thermostat operation
¡
Operating conditions
If the inverter command speed obtained with the fuzzy calculation drops below -24 rps during the heating fuzzy operation,
the operation changes to the heating thermostat operation.
¡
Detail of operation
4.8 Outline of heating operation
(1)
Operation of major functional components in heating mode
(2)
Air flow selection
(a)
Speed of inverter changes within the range of selected air flow.
Item
Indoor fan motor
ON
ON
OFF
Flap and louver
ON or OFF
ON or OFF
Stop position control
Display
Lights up
Lights up
Lights up or flashes
Outdoor fan motor
ON
4-way valve
Depending on the stop mode
ON
Depending on the stop mode
Electronic expansion valve
Depending on the EEV control
When the inverter
speed is 0rps
When the inverter speed
is other than 0rps
When the inverter speed is 0rps
due to an anomalous stop
Functional
components
(b)
When the defrosting, protection device, etc. is actuated, operation is performed in the corresponding mode.
(c)
Outdoor unit blower operates in accordance with the inverter command speed.
Model
SRK63ZEA-S1
SRK71ZEA-S1
Air flow selection
Inverter command speed
12~88rps
12~95rps
Air flow
Depends on inverter command speed.
Inverter command speed
12~88rps
12~95rps
Air flow
9th speed fixed
Inverter command speed
12~88rps
12~95rps
Air flow
7th speed fixed
Inverter command speed
12~74rps
12~80rps
Air flow
5th speed fixed
ULO
Inverter command speed
12~40rps
Air flow
3rd speed fixed
Auto
HI
MED
LO
Model
SRK63ZEA-S1, 71ZEA-S1
Item
Inverter command speed
0rps [Comp. stopped]
Indoor fan motor
Hot keep N or M mode
→
1st speed
Outdoor fan motor
Stop
Flap and louver
Horizontal, center
Summary of Contents for SRK63ZEA-S1
Page 2: ...TECHNICAL MANUAL...
Page 59: ...57 Service data record form 0 1 2 3 4 5 6 7...
Page 84: ...PARTS LIST SRK63ZEA S1 SRK71ZEA S1 SRC63ZEA S1 SRC71ZEA S1...
Page 88: ...MEMO 86...
Page 94: ...MEMO 92...
Page 105: ...MEMO...
Page 106: ...Manual No 06 SRK T 053 ROOM AIR CONDITIONING TECHNICAL MANUAL PARTS LIST...