21
-
When the compressor is operating
When the compressor is stopped
(Including protection stoppage)
Inverter command speed
20 rps
0 rps
Indoor fan motor
OFF
Outdoor fan motor
3rd speed
Determined by heating stop mode
Flap and louver
Horizontal/ Center
4-way valve
ON
Determined by heating stop mode
(a)
Fan operation
1
1)
Operation content
Inverter command speed
0 rps
Indoor fan motor
1st speed
Outdoor fan motor
OFF
Flap and louver
Fully closed/ Center
(b)
Cooling operation
1)
Operation content
Inverter command speed
20 rps
Indoor fan motor
2nd speed
Outdor fan motor
3rd speed
Flap and louver
Horizontal/Center
4-way valve
OFF
Note (1)
During cooling operation safety control,frost
prevention control, and cooling overload
protective control are generally not applicable
(c)
Heating cycle operation
1)
Operation content
T
1
T
2
42min.
Time
Stop
Compressor operation
2)
Operation time
After cooling operation
(outdoor temperature–indoor
temperature)
T
1
(Compressor operation time)
T
2
(Compressor stopped time)
Heating operation control time (T
1
+T
2
)
–12°C
~
–10°C
80
2440
~
–12°C
90
2430
–10°C
~
–8°C
70
2450
–8°C
~
–6°C
60
2460
–6°C
~
–4°C
50
2470
42min.
–4°C
~
–2°C
40
2480
–2°C
~
0°C
30
2490
0°C
~
4°C
20
2500
4°C
~
9°C
10
2510
(Sec.)
Summary of Contents for SRK63ZEA-S1
Page 2: ...TECHNICAL MANUAL...
Page 59: ...57 Service data record form 0 1 2 3 4 5 6 7...
Page 84: ...PARTS LIST SRK63ZEA S1 SRK71ZEA S1 SRC63ZEA S1 SRC71ZEA S1...
Page 88: ...MEMO 86...
Page 94: ...MEMO 92...
Page 105: ...MEMO...
Page 106: ...Manual No 06 SRK T 053 ROOM AIR CONDITIONING TECHNICAL MANUAL PARTS LIST...