31
9.16. Return to the Home position
Return the robot to the Home position that set beforehand. The robot is initiated a joint interpolation movement to
the position set by the parameter "JSAFE". The speed is determined by the override setting.
This function is available with Ver.2.3or later of this software.
Please refer to
of the parameter for the setting of the safe position.
The Home position return is operated according to the following procedures.
(1) Set the MODE changeover switch to MANUAL.
(2) Push the [TEACH] switch (<a>) of T/B, and confirm that the [TEACH] switch and the [TB ENABLE] lamps light.
(3) Select the model of the operated robot.
When the multi-mechanism control is used, select the model of the operated robot by the combobox of the
model selection in the upper part of the screen. If the multi-mechanism control is not used, you don’t have to
select the model.
(4) The [JOG] button (<b >) is pushed, and the JOG operation screen is displayed.
(5) In the condition that the enable switch is pushed, press the [SERVO] button (<c>) of T/B, and the servo of robot
is turned ON. Please confirm the [SERVO] lamp lights.
(6) In the condition that the enable switch is pushed, press the [HOME] button (<d>) of T/B.
When the enable switch or the [HOME] button is detached, the robot stops.
Only when MELFA-BASIC V or MELFA-BASIC IV is set to the robot program language used, the
Home position return function can be used. The Home position return function cannot be used by
the MOVEMASTER command.
CAUTION
<b>
<a>
<a>
<c>
<d>
Summary of Contents for R56TB
Page 1: ...Mitsubishi Industrial Robot CR750 CRn 700 Series R56TB R57TB Instruction Manual BFP A8684 F...
Page 4: ...8 CAUTION CAUTION WARNING...
Page 6: ......
Page 12: ......
Page 126: ...114 Current2 a...
Page 173: ...161 17 4 9 5 Hand 17 4 9 6 Warm up...
Page 174: ...162 17 4 9 7 Start each slot 17 4 9 8 Stop each slot...
Page 175: ...163 17 4 9 9 Servo ON OFF each robot 17 4 9 10 Machine lock each robot...
Page 179: ...167...