2 - 2 2 - 2
MELSEC-Q
2 SYSTEM CONFIGURATION
Applicable CPU module
Base unit
*
2
CPU type
CPU model
No. of modules
*
1
Main base unit Extension base unit
Q06CCPU-V
C Controller module
Q06CCPU-V-B
Up to 64
: Applicable, : N/A
*1: Limited within the range of I/O points for the CPU module.
*2: Can be installed to any I/O slot of a base unit.
*3: Use the QD60P8-G module whose serial No. (first five digits) is 09012
or later.
(b) Mounting to a MELSECNET/H remote I/O station
The table below shows the network modules and base units applicable to
the QD60P8-G and quantities for each network module model.
Depending on the combination with other modules or the number of
mounted modules, power supply capacity may be insufficient.
Pay attention to the power supply capacity before mounting modules, and if
the power supply capacity is insufficient, change the combination of the
modules.
Base unit
*
2
Applicable network
module
No. of modules
*
1
Main base unit of
remote I/O station
Extension base unit of
remote I/O station
QJ72LP25-25
QJ72LP25G
QJ72LP25GE
QJ72BR15
Up to 64
: Applicable, : N/A
*1: Limited within the range of I/O points for the network module.
*2: Can be installed to any I/O slot of a base unit.
REMARK
The Basic model QCPU or C Controller module cannot create the MELSECNET/H
remote I/O network.
2
Summary of Contents for QD60P8-G
Page 1: ......
Page 2: ......
Page 14: ...A 12 A 12 MEMO ...
Page 18: ...1 4 1 4 MELSEC Q 1 OVERVIEW MEMO ...
Page 95: ...7 12 7 12 MELSEC Q 7 PROGRAMMING MEMO ...
Page 115: ...9 7 9 7 MELSEC Q 9 TROUBLESHOOTING MEMO ...
Page 121: ...App 2 App 2 MELSEC Q APPENDIX MEMO App ...
Page 124: ...Index 3 Index 3 MEMO ...
Page 127: ......