background image

Warranty
Mitsubishi will not be held liable for damage caused by factors found not to be the
cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi
products; damage, secondary damage, accident compensation caused by special
factors unpredictable by Mitsubishi; damages to products other than Mitsubishi
products; and to other duties.

For safe use

!

 This product has been manufactured as a general-purpose part for general industries,

and has not been designed or manufactured to be incorporated in a device or system
used in purposes related to human life.

!

 Before using the product for special purposes such as nuclear power, electric power,

aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.

!

 This product has been manufactured under strict quality control. However, when

installing the product where major accidents or losses could occur if the product fails,
install appropriate backup or failsafe functions in the system.

U.S.A 

 

Mitsubishi Electric Automation Inc.

 

 

500 Corporate Woods Parkway Vernon 

 

 

Hills, IL 60061

  

Tel 

+1-847-478-2100

Brazil 

 

MELCO-TEC Rep. Com.e Assessoria 

  

Tecnica 

Ltda.

 

 

Av. Rio Branco, 123-15 ,and S/1507, 

 

 

Rio de Janeiro, RJ CEP 20040-005, 

  

Brazil

  

Tel 

+55-21-221-8343

Germany   

Mitsubishi Electric Europe B.V. German 

  

Branch

 

 

Gothaer Strasse 8 D-40880 Ratingen, 

  

GERMANY

  

Tel 

+49-2102-486-0

U.K 

 

Mitsubishi Electric Europe B.V. UK 

  

Branch 

 

 

Travellers Lane, Hatfield, Herts., AL10 

  

8XB,UK

  

Tel 

+44-1707-276100

Italy 

 

Mitsubishi Electric Europe B.V. Italian 

  

Branch 

 

 

Centro Dir. Colleoni, Pal. Perseo - Ingr.2

 

 

Via Paracelso 12, 20041 Agrate B., 

  

Milano, 

Italy

  

Tel:+39-039-60531

Spain 

 

Mitsubishi Electric Europe B.V. Spanish 

 

 

Branch Carretera de Rubi 76-80

 

 

08190 - Sant Cugat del Valles, 

  

Barcelona, 

Spain

  

Tel:+34-935-653135

South Africa 

Circuit Breaker Industries LTD.

 

 

Private Bag 2016, Isando 1600, 

  

Johannesburg, 

South 

Africa

  

Tel 

+27-11-928-2000

Hong Kong 

Ryoden Automation Ltd.

 

 

10th Floor, Manulife Tower, 169 Electric 

 

 

Road, North Point, HongKong

  

Tel 

+852-2887-8870

China 

 

Ryoden International Shanghai Ltd.

 

 

3F Block5 Building Automation 

 

 

Instrumentation Plaza 103 Cao Bao Rd. 

 

 

Shanghai 200233 China

 

 

Tel : +86-21-6475-3228

Taiwan 

 

Setsuyo Enterprise Co., Ltd.

 

 

6F., No.105 Wu-Kung 3rd.RD, Wu-Ku 

 

 

Hsiang, Taipei Hsine, Taiwan

  Tel 

+886-2-2299-2499

Korea 

 

HAN NEUNG TECHNO CO.,LTD.

 

 

1F Dong Seo Game Channel Bldg., 

  660-11, 

Deungchon-dong 

Kangsec-ku,

  Seoul, 

Korea

  Tel 

+82-2-3668-6567

Singapore 

Mitsubishi Electric Asia Pte, Ltd.

  307 

ALEXANDRA 

ROAD 

#05-01/02, 

  MITSUBISHI 

ELECTRIC 

BUILDING 

  SINGAPORE 

159943

  Tel 

+65-473-2480

Thailand  

F. A. Tech Co.,Ltd.

  898/28,29,30 

S.V.City 

Building,Office 

 

 

Tower 2,Floor 17-18 Rama 3 Road, 

  Bangkpongpang, 

Yannawa, 

  Bangkok 

10120

  Tel 

+66-2-682-6522

Indonesia 

P.T. Autoteknindo SUMBER MAKMUR

 

 

Jl. Muara Karang Selatan Block A Utara 

 

 

No.1 Kav. No.11 Kawasan Industri/ 

 

 

Pergudangan Jakarta - Utara 14440

  Tel 

+62-21-663-0833

India  

Messung 

Systems 

Put,Ltd.

  Electronic 

Sadan 

NO:111 

Unit 

No15, 

  M.I.D.C 

BHOSARI,PUNE-411026

  Tel 

+91-20-7128927

Australia  

Mitsubishi Electric Australia Pty. Ltd.

 

 

348 Victoria Road, PostalBag, No 2, 

  Rydalmere, 

N.S.W 

2116, 

Australia

  Tel 

+61-2-9684-7777

Country/Region Sales office/Tel

Country/Region Sales office/Tel

When exported from Japan, this manual does not require application to the Ministry 
of Economy, Trade and Industry for service transaction permission.

Specifications subject to change without notice.

Printed in Japan on recycled paper.

HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212, JAPAN

NAGOYA WORKS : 1-14, YADA-MINAMI5, HIGASHI-KU, NAGOYA, JAPAN

Summary of Contents for Q64TD

Page 1: ...OLLER User s Manual Hardware Q64TD Q64TDV GH Thank you for purchasing the Mitsubishi general purpose programmable logic controller MELSEC Q series Prior to use please read this manual thoroughly and familiarize yourself with the product MODEL Q64TD U H JE MODEL CODE 13JT30 IB NA 0800155 B 0201 MEE 2000 MITSUBISHI ELECTRIC CORPORATION ...

Page 2: ...d by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage Store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user DESIGN PRECAUTIONS DANGER Do not write data into the system area of the buffer memory of intelligent function modules Also do not use any prohibited to use sig...

Page 3: ...or the module resulting in fallout short circuits or malfunction Switch all phases of the external power supply off when mounting or removing the module Not ding so may cause electric shock or damage to the module Do not directly touch the conductive area or electronic components of the module Doing so may cause malfunction or failure in the module WIRING PRECAUTIONS CAUTION Always ground the FG t...

Page 4: ...t Not doing so will make the module more susceptible to noises surges and inductions REVISIONS The manual number is given on the bottom right of the top cover Print Date Manual Number Revision Nov 2000 IB NA 0800155 A First edition Jan 2002 IB NA 0800155 B Model Q64TDV GH was added Addition Section2 2 Correction About the Manuals Chapter1 Section2 1 Chapter4 Section5 1 Section5 2 Section5 3 Chapte...

Page 5: ...red temperature range accuracies 2 2 2 Specifications of Q64TDV GH 3 2 2 1 Performance specifications 3 2 2 2 Usable thermocouples and measured temperature range accuracies 5 2 2 3 Micro voltage input range and accuracies 5 3 LOADING AND INSTALLATION 6 3 1 Handling Instructions 6 3 2 Installation Environment 6 4 NAMES AND SETTINGS OF THE PARTS 7 5 WIRING 8 5 1 Wiring Instructions 8 5 2 External Wi...

Page 6: ...64TDV GH GX Configurator TI SW1D5C QTIU E SH 080141 13JR30 Conformance to the EMC Directive Low Voltage Directive For details on making Mitsubishi PLC conform to the EMC directive and low voltage instruction when installing it in your product please see Chapter 3 EMC Directive and Low Voltage Instruction of the User s Manual Hardware of the PLC CPU to use The CE logo is printed on the rating plate...

Page 7: ...tage 1780VrmsAC 3 cycles altitude 2000m Insulation resistance Across thermocouple input and earth Across thermocouple input channels 500VDC 100MΩ or more using insulation resistance tester 500VDC 10MΩ or more using insulation resistance tester Wire break detection Yes Each channel independent 3 E 2 PROM write count Max 100 thousand times Number of occupied points 16 points Connection terminals 18 ...

Page 8: ... value of 0 5 and 0 25 of measured temperature Larger value of 0 06 and 0 02 of measured temperature 6 75 E 900 to 1000 3 3 3 210 to 40 3 3 3 40 to 750 2 Larger value of 0 5 and 0 25 of measured temperature Larger value of 0 06 and 0 02 of measured temperature 5 625 J 750 to 1200 3 3 3 270 to 200 3 3 3 200 to 0 2 Larger value of 0 5 and 0 5 of measured temperature Larger value of 0 06 and 0 1 of m...

Page 9: ...hannels Across cold junction temperature compensation input Pt100 and earth Transformer insulation Transformer insulation No insulation Dielectric withstand voltage 1780VrmsAC 3 cycles altitude 2000m Insulation resistance Across thermocouple input micro voltage input and earth Across thermocouple input micro voltage input channels 500VDC 100MΩ or more using insulation resistance tester 500VDC 10MΩ...

Page 10: ... into the buffer memory The conversion speed is a delay time that occurs during sampling processing It is independent of averaging processing Example When two channels are enabled for conversion Conversion speed sampling period 3 20ms 2 channels 3 120ms CH 1 CH 2 Input 1 Conversion speed Conversion processing Buffer memory Input 2 CH 1 CH 2 CH 1 CH 2 CH 1 CH 2 CH 1 CH 2 Input 1 Input 2 Conversion ...

Page 11: ... 5 25 200 to 900 2 2 0 0 15 5 75 E 900 to 1000 3 3 3 210 to 40 3 3 3 40 to 200 2 1 5 5 25 200 to 750 2 2 0 0 15 5 75 J 750 to 1200 3 3 3 270 to 200 3 3 3 200 to 0 2 2 0 4 5 0 to 350 2 1 5 0 1 4 0 T 350 to 400 3 3 3 270 to 200 3 3 3 200 to 0 2 2 5 8 75 0 to 200 2 2 0 8 25 0 to 1250 2 2 5 0 25 8 75 N 1250 to 1300 3 3 3 1 If a value entered from the thermocouple is outside the measured temperature ra...

Page 12: ...evention label at its top During wiring do not remove this label For system operation always remove this label to ensure adequate heat dissipation 5 Tighten the mounting and terminal screws of the module within the following ranges Screw Location Tightening Torque Range Module mounting screw M3 screw 36 to 48 N cm Terminal block terminal screw M3 screw 42 to 58 N cm Terminal block mounting screw M...

Page 13: ...Q64TDV GH Number Name and Appearance Description 1 RUN LED Indicates the operating status of the Q64TD Q64TDV GH On Operating normally Flicker Offset gain setting mode Off 5V power off Watchdog timer error occurrence or module change enabled status during online module change 2 ERR LED Indicates the error status of the Q64TD Q64TDV GH On Error occurrence Flicker Switch setting error Switch 5 was s...

Page 14: ...inverter s load circuit Not doing so will make the module more susceptible to noises surges and inductions 3 Insulation sleeved crimping terminals cannot be used with the terminal block It is recommended to fit mark tubes or insulation tubes to the wire connection parts of the crimping terminals 5 2 External Wiring 1 Thermocouple RTD Input amplifier CH1 Filter Transformer CH4 Pt100 1 2 1 As cables...

Page 15: ...er CH4 Pt100 1 2 1 As cables always use shielded conductors Also wire the shielded cables as short as possible 2 Always connect to the earth terminal of the control box SLD SLD FG Input amplifier Input amplifier Filter Transformer Load cell or like Load cell or like ...

Page 16: ...e B 4 Thermocouple R 5 Thermocouple S 6 Thermocouple N 7 Micro voltage input 8 Switch 1 Input type setting CH4 CH3 CH2 CH1 H Offset gain setting Set value Factory setting 0 User setting 1 Switch 2 Offset gain setting CH4 CH3 CH2 CH1 H Switch 3 Empty Switch 4 H 0H With cold junction temperature compensation 1 to FH Without cold junction temperature compensation 0H Normal mode 1 to FH Offset gain se...

Page 17: ...H1 CH2 1 2 SLD SLD CH3 CH4 3 4 SLD SLD FG Q64TD 2 0 08 112 4 41 98 3 86 105 4 14 2 0 08 5 0 20 Unit mm in 2 Q64TDV GH 27 4 1 08 Q64TDV GH RUN ERROR 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 R T D CH1 CH2 1 2 SLD SLD CH3 CH4 3 4 SLD SLD FG Q64TDV GH 2 0 08 112 4 41 98 3 86 105 4 14 2 0 08 5 0 20 Unit mm in ...

Page 18: ... V Spanish Branch Carretera de Rubi 76 80 08190 Sant Cugat del Valles Barcelona Spain Tel 34 935 653135 South Africa Circuit Breaker Industries LTD Private Bag 2016 Isando 1600 Johannesburg South Africa Tel 27 11 928 2000 Hong Kong Ryoden Automation Ltd 10th Floor Manulife Tower 169 Electric Road North Point HongKong Tel 852 2887 8870 China Ryoden International Shanghai Ltd 3F Block5 Building Auto...

Reviews: