background image

9

ON

Hr

AFTER

SIMPLE

Timer Setting

Action (On or Off)

* “— —” is displayed if there is no 

setting.

Timer Settings

Û

F

TIMER

SUN

ON

OFF

WEEKLY

Û

F

Û

F

TIME SUN

WEEKLY

Û

F

Û

F

TIME SUN

WEEKLY

6. Timer

ON

Hr

AFTER

SIMPLE

PAR-21MAA

ON/OFF

FILTER

CHECK

OPERATION

CLEAR

TEST

TEMP.

MENU

BACK

DAY

MONITOR/SET

CLOCK

ON/OFF

1. Be sure that the weekly timer indicator is visible on the screen (at 

 

).

2. Press the Timer Menu button 

 so that “Monitor” is indicated on the 

screen (at 

).

3. Press the Timer On/Off (Set Day) button 

 as necessary to select the 

day you wish to view.

4. Press the 

 or 

 Operation button (

 or 

) as necessary to change 

the timer operation shown on the display (at 

 ).

* Each press will advance to the next timer operation, in order of time 

setting.

5. To close the monitor and return to the standard control screen, press 

the Operation mode (Back) button 

.

<To Turn Off the Weekly Timer>
Press the Timer On/Off button 

 so that “Timer Off” appears at  .

<To Turn On the Weekly Timer>
Press the Timer On/Off button 

  so that the “Timer Off” indication (at  )

goes dark.

6.1.2. Simple Timer

 You can set the simple timer in any of 3 ways.
• Start time only:

The air conditioner starts when the set time has elapsed.

• Stop time only:

The air conditioner stops when the set time has elapsed.

• Start & stop times:

The air conditioner starts and stops at the respective elapsed times.

The simple timer (start and stop) can be set only once within a 
72-hour period. 
The time setting is made in hour increments.

Note:
*1. Weekly Timer/Simple Timer/Auto Off Timer cannot be used at 

the same time. 

*2. The simple timer will not operate when any of the following con-

ditions is in effect. 
The timer is off; the system is in malfunction state; a test run is 
in progress; the remote controller is undergoing self-check or 
remote controller check; the user is in the process of selecting 
a function; the user is in the process of setting the timer; the 

V\VWHPLVXQGHUFHQWUDOFRQWURO8QGHUWKHVHFRQGLWLRQV2Q2II
RSHUDWLRQLVSURKLELWHG

<How to Set the Simple Timer>

1.  Be sure that you are at a standard control screen, and that the simple 

timer indicator is visible in the display (at 

 

).

When something other than the Simple Timer is displayed, set it to 
SIMPLE TIMER using the function selection of remote controller (see 
8.[4]–3 (3)) timer function setting. 

2. Press the Timer Menu button 

, so that the “Set Up” appears on the 

screen (at 

). (Note that each press of the button toggles the display 

between “Set Up” and “Monitor”.)

3. Press the ON/OFF button 

 to display the current ON or OFF simple 

timer setting. Press the button once to display the time remaining to 
ON, and then again to display the time remaining to OFF. (The ON/
OFF indication appears at 

).

“ON” timer:

7KHDLUFRQGLWLRQHUZLOOVWDUWRSHUDWLRQZKHQWKHVSHFL¿HGQXPEHURI

hours has elapsed.

“OFF” timer:

7KHDLUFRQGLWLRQHUZLOOVWRSRSHUDWLRQZKHQWKHVSHFL¿HGQXPEHURI

hours has elapsed.

4. With “ON” or “OFF” showing at 

: Press the appropriate Set Time 

button

 as necessary to set the hours to ON (if “ON” is displayed) or 

the hours to OFF (if “OFF” is displayed) at 

.

Available Range: 1 to 72 hours

5. To set both the ON and OFF times, repeat Steps 3 and 4. 
*

Note that ON and OFF times cannot be set to the same value.

6. To clear the current ON or OFF setting: Display the ON or OFF setting 

(see step 3) and then press the Check (Clear) button 

 so that the 

time setting clears to “—” at 

. (If you want to use only an ON setting 

or only an OFF setting, be sure that the setting you do not wish to use 
is shown as “—”.)

<Setting the Weekly Timer>

5. Press the appropriate Set Time button 

 

 as necessary to set the de-

sired time (at 

).

 $V\RXKROGWKHEXWWRQGRZQWKHWLPH¿UVWLQFUHPHQWVLQPLQXWHLQ

-

tervals, then in ten-minute intervals, and then in one-hour intervals.

6. Press the ON/OFF button 

 to select the desired operation (ON or 

OFF) at 

.

* Each press changes the next setting, in the following sequence: No 

display (no setting) 

 “ON”

 “OFF”

7. Press the appropriate Temperature set button 

 to set the desired 

temperature (at 

 ).

* Each press changes the setting, in the following sequence: No dis-

play (no setting) 

 75 

 77 

 ... 

  84 

 87 

 53 

  ... 

 73 

 No display.

(Available range: The range for the setting is 12°C, 54°F to 30°C, 
86°F. The actual range over which the temperature can be control-
led, however, will vary according to the type of the connected unit.)

8. After making the appropriate settings at Steps 5, 6 and 7, press the 

Filter

 button 

 to lock in the values.

To clear the currently set values for the selected operation, press and 
quickly release the Check (Clear) button 

 once. 

* The displayed time setting will change to “—:—”, and the On/Off 

and temperature settings will all disappear.
(To clear all weekly timer settings at once, hold down the Check 
(Clear) button 

 for two seconds or more. The display will begin 

blinking, indicating that all settings have been cleared.)

Note:
Your new entries will be cancelled if you press the Operation mode 

%DFNEXWWRQ

 before pressing the Filter   button 

.

If you have set two or more different operations for exactly the 
same time, only the operation with the highest Operation No. will be 
carried out.

 5HSHDW6WHSVWRDVQHFHVVDU\WR¿OODVPDQ\RIWKHDYDLODEOHFHOOV

as you wish.

10. Press the Operation mode (Back) button 

 to return to the standard 

control screen and complete the setting procedure.

11. To activate the timer, press the Timer On/Off button 

, so that the 

“Timer Off” indication disappears from the screen. 

Be sure that the 

“Timer Off” indication is no longer displayed.

* If there are no timer settings, the “Timer Off” indication will blink on 

the screen.

<How to View the Weekly Timer Settings>

Summary of Contents for PKFY-NBMU-E2

Page 1: ...lire le manuel d utilisation en entier avant de vous servir du climatiseur MANUAL DE INSTRUCCIONES HD HVWH PDQXDO GH LQVWUXFFLRQHV KDVWD HO QDO DQWHV GH SRQHU HQ PDUFKD OD XQLGDG GH DLUH DFRQGLFLRQDGR...

Page 2: ...en installing or relocating or servicing the air conditioner use RQO WKH VSHFL HG UHIULJHUDQW 5 WR FKDUJH WKH UHIULJHUDQW lines Do not mix it with any other refrigerant and do not allow air to remain...

Page 3: ...2 Wall Mounted PMFY P NBMU E 1 way Ceiling Cassette Filter Air inlet Louver Air outlet Vane Filter Air intake Louver Air outlet Vane 2 Parts Names PKFY P NHMU E2 Wall Mounted Filter Air intake Louver...

Page 4: ...tion Temperature set buttons Down Up Set Time buttons Timer On Off button Set Day button Opening the door ON OFF button Fan Speed button Filter button Enter button Test Run button Check button Clear b...

Page 5: ...on do not get the remote controller wet or leave it in a location with high hu midity To avoid misplacing the remote controller install the holder included with the remote controller on a wall and be...

Page 6: ...ns etc Set Day Time Set the current day of the week or time Standard Control Screens View and set the air conditioning system s op erating status Timer Monitor View the currently set timer weekly time...

Page 7: ...display blinks either 8 C 39 C 46 F 102 F to inform you if the room temperature is lower or higher than the displayed temperature DQ VSHHG VHWWLQJ Press the Fan Speed button as many times as necessary...

Page 8: ...UDWXUH VHWWLQJ WKDW DUH SURKLELWHG GXULQJ WKHVH FRQGLWLRQV F SUN ON WEEKLY PAR 21MAA ON OFF FILTER CHECK OPERATION CLEAR TEST TEMP MENU BACK DAY MONITOR SET CLOCK ON OFF Operation No Day Setting 6 Tim...

Page 9: ...ON timer 7KH DLU FRQGLWLRQHU ZLOO VWDUW RSHUDWLRQ ZKHQ WKH VSHFL HG QXPEHU RI hours has elapsed OFF timer 7KH DLU FRQGLWLRQHU ZLOO VWRS RSHUDWLRQ ZKHQ WKH VSHFL HG QXPEHU RI hours has elapsed 4 With O...

Page 10: ...s countdown when the air conditioner starts and shuts the air conditioner off when the set time has elapsed Available settings run from 30 minutes to 4 hours in 30 minute intervals Note 1 Weekly Timer...

Page 11: ...he lock type see section 8 item 4 2 1 6SHFL FDOO RX FDQ XVH HLWKHU RI WKH IROORZLQJ WZR ORFN W SHV Lock All Buttons Locks all of the buttons on the remote controller Lock All Except ON OFF Locks all b...

Page 12: ...he use or non use of clock function 3 Timer function setting WEEKLY TIMER Setting the timer type 4 Contact number setting for error situation CALL Contact number display in case of error Setting the t...

Page 13: ...e is displayed when the operation mode is selected Initial setting value The automatic mode is not displayed when the operation mode is selected The temperature range limit is not active Initial setti...

Page 14: ...to change the language English GB German D Spanish E Russian RU Italian I Chinese CH French F Japanese JP Refer to the dot display table 4 2 Function limit 1 Operation function limit setting operatio...

Page 15: ...ing day mode Limit temperature heating mode Limit temperature auto mode Operation mode selection Remote controller setting MAIN Remote controller setting SUB Use of clock setting Setting the day of th...

Page 16: ...ILTER indicates the cleaning period when the air conditioner was used under general indoor air conditions by criteria time Since the degree of dirtiness depends on the environmental con GLWLRQV FOHDQ...

Page 17: ...ing cooling mode the vanes automatically move to the horizontal GRZQ SRVLWLRQ DIWHU KRXU ZKHQ WKH GRZQ KRUL RQWDO DLU RZ GLUHFWLRQ is selected This is to prevent water from forming and dripping from t...

Page 18: ...MPLE or AUTO OFF appears in the remote controller display PLEASE WAIT appears in the remote controller display The initial settings are being performed Wait approximately 3 minutes An error code appea...

Page 19: ...igh dB A 27 30 33 35 32 34 36 37 33 35 37 39 1 Cooling Heating capacity indicates the maximum value at operation under the following condition Coolong Indoor 27 C DB 81 F DB 19 C WB 67 F WB Outdoor 35...

Page 20: ...XU GH OD VHPDLQH HW O KHXUH 24 5 Fonctionnement 24 6 Minuterie 26 7 Autres fonctions 29 8 S lection des fonctions 30 RQFWLRQQHPHQW G XUJHQFH GH OD WpOpFRPPDQGH VDQV O 34 10 Entretien et nettoyage 34 1...

Page 21: ...ilter Air intake Louver Air outlet Vane 2 Nomenclature 3 3 1 08 Fix au Mur Filter Air intake Louver Air outlet Vane Filtre Ailette Grille de re IRXOHPHQW G DLU Louvre GPLVVLRQ G DLU Filtre Ailette Gri...

Page 22: ...AVAILABLE NON DISPONIBLE H PHVVDJH V DI FKH TXDQG YRXV DSSX H VXU XQH WRXFKH SRXU ODQFHU XQH IRQFWLRQ TXL HVW LQGLVSRQLEOH SRXU FHW DSSDUHLO LQWpULHXU RUVTX XQH WpOpFRPPDQGH XQLTXH HVW XWLOLVpH SRXU...

Page 23: ...H pile Ins rez les piles en respectant la polarit LQGLTXpH SSX H VXU OD WRXFKH Reset R initialiser DYHF XQ REMHW GRQW O H tr mit est troite 3RXU XWLOLVHU OD WpOpFRPPDQGH VDQV O SRLQWH OD YHUV OH UpFHS...

Page 24: ...eur I FKH OH SURJUDPPDWHXU HQ SODFH KHEGRPD GDLUH VLPSOH RX DUUrW DXWRPDWLTXH RQ JXUDWLRQ GX SURJUDPPDWHXU R gle le fonctionnement des programmateurs KHEGRPDGDLUH VLPSOH RX DUUrW DXWRPDWLTXH Comment c...

Page 25: ...XU OH ERXWRQ YRXV FKDQJH OD force La vitesse actuelle est indiqu e en D VpTXHQFH GH FKDQJHPHQW HW OHV UpJODJHV GLVSRQLEOHV VRQW OHV VXLYDQWV Vitesse du ventilateur I FKDJH 4 vitesses Auto 3 vitesses A...

Page 26: ...ER CHECK OPERATION CLEAR TEST TEMP MENU BACK DAY MONITOR SET CLOCK ON OFF Operation No Day Setting 6 Minuterie 5 Fonctionnement 5pJODJH GH O RSpUDWLRQ SRXU GLPDQFKH pPDUUHU OH FRQGLWLRQQHXU G DLU j DY...

Page 27: ...0DUFKH H FRQGLWLRQQHXU G DLU GpPDUUH TXDQG OH QRPEUH G KHXUHV LQGLTXp V HVW pFRXOp Programmateur Arr t H FRQGLWLRQQHXU G DLU V DUUrWH TXDQG OH QRPEUH G KHXUHV LQGLTXp V HVW pFRXOp 4 YHF O LQGLFDWLRQ 0...

Page 28: ...H OH FRPSWH j UHERXUV DX GpPDUUDJH GX FRQGL WLRQQHXU G DLU HW pWHLQW OH FRQGLWLRQQHXU TXDQG OH WHPSV LQGLTXp V HVW pFRXOp OHV UpJODJHV SRVVLEOHV YRQW GH PLQXWHV j KHXUHV SDU WUDQFKHV GH 30 minutes 5HP...

Page 29: ...H G pWHLQGUH OH FRQGLWLRQQHXU G DLU OXL PrPH D valeur du programmateur en GLVSDUDvWUD GH O pFUDQ Pour d marrer le programmateur Arr t Auto SSX H VXU OH ERXWRQ 0DUFKH UUrW GX SURJUDPPDWHXU pendant 3 se...

Page 30: ...ORLOGE FWLYDWLRQ RX GpVDFWLYDWLRQ GH OD IRQFWLRQ G KRUORJH 3 R glage de la fonction de minuterie PROG HEBDO MADAIRE R glage du type de minuterie 4 5pJODJH GX QXPpUR j FRQWDFWHU HQ FDV G HU reur CALL I...

Page 31: ...GH DXWRPDWLTXH Le param trage de verrouillage des op rations est inactif Valeur de param trage initiale Le param trage de verrouillage des op rations est actif sauf pour OHV WRXFKH 2Q 2II 0DUFKH UUrW...

Page 32: ...RQQpH SSX H VXU OD WRXFKH 0 18 SRXU PRGL HU OD ODQJXH QJODLV OOHPDQG VSDJQRO 5XVVH 58 WDOLHQ KLQRLV UDQoDLV Japonais JP RQVXOWH OH WDEOHDX G DI FKDJH SDU SRLQW Limitation des fonctions 1 R glage de la...

Page 33: ...FKDXIIDJH Limites de temp rature mode refroidissement Limites de la plage de temp rature S lection du mode automatique Blocage des fonctions S lection des fonctions 0RGL FDWLRQ GH OD ODQJXH Langue par...

Page 34: ...VW UpLQLWLDOLVpH 7 5 OWUH LQGLTXH OD SpULRGH HQWUH OHV QHWWR DJHV HQ KHXUH si le climatiseur est utilis dans des conditions d air int rieur nor males Toutefois le degr d encrassement du filtre d pend...

Page 35: ...DWLTXHPHQW HQ SRVLWLRQ KRUL RQWDOH EDVVH DX ERXW G XQH KHXUH ORUVTX XQH GLUHFWLRQ GH GpELW G DLU EDVVH KRUL RQWDOH HVW VpOHFWLRQQpH HFL pYLWH OD IRUPDWLRQ G HDX VXU OHV DLOHWWHV HW SUpYLHQW WRXW VXLQW...

Page 36: ...LE ou AUTO OFF GRLYHQW DSSDUDvWUH VXU O pFUDQ GH OD WpOpFRPPDQGH Le message PLEASE WAIT VEUILLEZ PATIENTER appara t sur O pFUDQ GH OD WpOpFRPPDQGH HV SDUDPpWUDJHV LQLWLDX VRQW HQ FRXUV G H pFXWLRQ 3DW...

Page 37: ...GH UHIURLGLVVHPHQW FKDXIIDJH LQGLTXH OD YDOHXU PD LPDOH ORUVTXH O DSSDUHLO IRQFWLRQQH GDQV OHV FRQGLWLRQV VXLYDQWHV Refroidissement appareil int rieur appareil ext rieur KDXIIDJH appareil int rieur a...

Page 38: ...bles etc 1R WRTXH HO GH HFWRU GH OD VDOLGD GH DLUH VXSHULRU QL OD FRPSXHUWD de la salida de aire inferior durante el funcionamiento De lo contrario podr a caer la condensaci n y la unidad podr a deten...

Page 39: ...ir outlet Vane Filter Air intake Louver Air outlet Vane 2 Nombres de las piezas PKFY P NHMU E2 Modelo montado en pared Filter Air intake Louver Air outlet Vane Salida de aire H HFWRU Rejilla Entrada d...

Page 40: ...O KD desactivado el funcionamiento del mando a distancia Indicador Timer Is Off Indica que el temporizador est desactivado RQ JXUDFLyQ GH WHPSHUDWXUD Muestra la temperatura objetivo Indicador de venti...

Page 41: ...O SXOVDU HO ERWyQ 5HVHW 5HVWDEOHFHU DSDUHFHQ todos los elementos en pantalla Cubierta superior XDQGR XWLOLFH HO FRQWURODGRU UHPRWR LQDOiPEULFR DSXQWH KDFLD HO UHFHSWRU GH OD XQLGDG LQWHULRU 6L HO FRQW...

Page 42: ...VXDOLFH HO WHPSRUL DGRU FRQ JXUDGR DFWXDOPHQWH VHPDQDO WHPSRUL DGRU VLPSOH R DSDJDGR DXWRPiWLFR Temporizador FRQ JXUH HO IXQFLRQDPLHQWR GH FXDOTXLHUD GH ORV WHP SRUL DGRUHV VHPDQDO VLPSOH R DSDJDGR DX...

Page 43: ...SHUDFLyQ FXDQGR VH DSDJXH OD SDQWDOOD GHO FRQWURODGRU UHPRWR MODELSELECT SDUSDGHD VH LOXPLQD HO Q GH PRGHOR 3XOVH HO ERWyQ 872 6723 SDUSDGHD VH LOXPLQD HO Q GH DMXVWH DMXVWH Q VLQ YHQWLODGRU HQ YHORFL...

Page 44: ...WLYDGDV FXDQGR VH SURGX FDQ HVWDV condiciones F SUN ON WEEKLY PAR 21MAA ON OFF FILTER CHECK OPERATION CLEAR TEST TEMP MENU BACK DAY MONITOR SET CLOCK ON OFF Operation No D 6HWWLQJ 6 Temporizador 5 Man...

Page 45: ...6yOR KRUD GH SDUDGD HO DFRQGLFLRQDGRU GH DLUH VH GHWHQGUi FXDQGR KD D WUDQVFXUULGR HO WLHPSR MDGR RUDV GH SXHVWD HQ PDUFKD GH SDUDGD HO DFRQGLFLRQDGRU GH DLUH FRPLHQ D D IXQFLRQDU VH GHWLHQH FXDQGR K...

Page 46: ...res 3XOVH HO ERWyQ 0RGR GH IXQFLRQDPLHQWR EDFN DWUiV para cerrar la SDQWDOOD GHO PRQLWRU UHJUHVDU D OD SDQWDOOD GH FRQWURO HVWiQGDU Para desactivar el temporizador simple 3XOVH HO ERWyQ 7LPHU 2Q 2II S...

Page 47: ...res 6L QR KD DMXVWDGR OD KRUD DFWXDO QR SRGUi XWLOL DU OD IXQFLyQ GHO WHP porizador 6 2 Para controlador remoto inal mbrico F RPSUREDFLyQ GH OD FRQ JXUDFLyQ DFWXDO GHO WHPSRUL DGRU GH DSDJDGR DXWRPiWL...

Page 48: ...02675 5 02 2 MXVWH GHO LQGLFDGRU GH WHPSHUDWXUD 7 03 5 26 MXVWH GH OD XQLGDG GH WHPSHUDWXUD R TXH GHEH DSD recer en el indicador Ajuste del indicador de temperatura del aire de DVSLUDFLyQ 02675 5 7 03...

Page 49: ...6758 21 6 GH SLH DV RSFLRQDOHV SDQHO Q HO PRGR DXWRPiWLFR VyOR DSDUHFH XWRPDWLF XWRPiWLFR O DMXVWH GH IXQFLyQ EORTXHDGD QR VH XWLOL D YDORU GH DMXVWH LQLFLDO O EORTXHR GH IXQFLRQDPLHQWR HVWi DMXVWDGR...

Page 50: ...OD WHPSHUDWXUD SRGUi DMXVWDUVH Rango ajustable 0RGR 5HIULJHUDFLyQ 6HFDGR tPLWH LQIHULRU D F a 87 F tPLWH VXSHULRU D F a 67 F 0RGR DOHIDFFLyQ tPLWH LQIHULRU D F a 83 F tPLWH VXSHULRU D F a 63 F Modo A...

Page 51: ...RU XWR UHYLVLyQ 6HOHFFLyQ GH IXQFLyQ HQ OD XQLGDG 8WLOL DFLyQ GHO DMXVWH GH PRGR autom tico Idioma ajustado 6HOHFFLyQ GH IXQFLyQ 6HOHFFLyQ GH 0RGR GH IXQFLRQDPLHQWR Cambio de idioma MXVWH GH OtPLWH GH...

Page 52: ...incipal aparece FILTER Filtro Cuando se apague HO LQGLFDGRU GHO OWUR HO WLHPSR DFXPXODGR VH UHDMXVWDUi FILTER Filtro indica el periodo de limpieza en que se us el ac ondicionador de aire bajo las cond...

Page 53: ...OD GLUHFFLyQ GH XMR GH DLUH LQIHULRU KRUL RQWDO H HVWD IRUPD VH HYLWD TXH VH DFXPXOH DJXD FDLJD GHVGH ORV GH HFWRUHV XUDQWH HO PRGR GH FDOHIDFFLyQ ORV GH HFWRUHV VH PXHYHQ DXWRPiWLFD PHQWH D OD SRVLF...

Page 54: ...el temporizador se puede ajustar WEEKLY SIMPLE o AUTO OFF aparecer n en la pantalla del controlador remoto Q OD SDQWDOOD GHO FRQWURODGRU UHPRWR DSDUHFH 3 6 7 325 925 63 5 6H KDQ UHDOL DGR ORV DMXVWHV...

Page 55: ...Pi LPR GHO IXQFLRQDPLHQWR EDMR ODV VLJXLHQWHV FRQGLFLRQHV 5HIULJHUDFLyQ Interior Exterior 35 C DB 95 F DB DOHIDFFLyQ Interior 20 C DB 68 F DB Exterior Margen de aplicaci n O PDUJHQ GH WHPSHUDWXUDV GH...

Page 56: ...on this manual before handing it to the customer Printed in Japan BG79U634H05 This product is designed and intended for use in the residential commercial and light industrial environment HEAD OFFICE T...

Reviews: